Trunk Configuration
Software Version: CPC-B Versions 4.0 to 6.02
Address:
Master Cabinet: FF1 8# 4# 4# 1# 1# (0 or 1)#
Slave Cabinet:
FF1 8# 4# 5# 1# 1# (0 or 1)#
Description
Specifies the trunk combinations used in the DBS system (analog trunks only
by default).
Setting this address to “T1 and Analog trunks” tells the DBS system that T1
and analog trunks are being used in the same cabinet. (Each T1 channel uses
up one trunk port on the analog trunk card.)
Programming
Related Programming
Number of T1 Channels: FF1 8# 4# (4 or 5)# 1# 2# (0-24)#
T1 Trunk Closure: FF1 8# 7# (1 or 2)# (1-4)# (1-8)# (0 or 1)#
Trunk Circuit Type: FF2 (Trunk)# 21# (0-3)#
Notes
Power-Cycling Requirement.
For changes to this parameter to take effect,
the system must be turned off, then back on.
CPC-B Versions Beginning With 6.03.
The
Trunk Configuration
address
is no longer present -- simply use the
Trunk Circuit Type
address to assign
trunk ports as Loop-Start, Ground-Start, DID or T1 trunks.
FF1 8# 4# (4 or 5)# 1# 1# (0 or 1)#
4=Master Cabinet
0=Analog trunks only.
5=Slave Cabinet 1=T1 and Analog trunks.
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...