Yellow Alarm Send
Software Version: CPC-B Version 4.0 or higher
Address:
Master Cabinet: FF1 8# 4# 4# 1# 7# (0 or 1)#
Slave Cabinet:
FF1 8# 4# 5# 1# 7# (0 or 1)#
Description
Determines whether the DBS sends a yellow alarm signal to the CO.
A yellow alarm is sent to the distant end of the T1 link to indicate that a red
alarm has occurred. If a red alarm occurs at the CO, the CO sends a yellow
alarm to the DBS. If a red alarm occurs at the DBS, the DBS sends a yellow
alarm to the CO.
Programming
Related Programming
Yellow Alarm Detection: FF1 8# 4# (4 or 5)# 2# 2# (0-15)#
Yellow Alarm Recovery: FF1 8# 4# (4 or 5)# 2# 3# (0-15)#
Yellow Alarm Counter: FF1 8# 4# (4 or 5)# 3# 6# (0-15)#
Yellow Alarm Relay: FF1 8# 4# (4 or 5)# 4# 1# (0-15)#
Yellow Alarm FF Key: FF5 (ExtPort)# (Key)# CONF (107# or 127#)#
FF1 8# 4# (4 or 5)# 1# 7# (0 or 1)#
4=Master Cabinet
5=Slave Cabinet
0=No
1=Yes