Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-190
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
DID/DNIS
Software Version: CPC-B Version 4.0 or higher
Address:
FF1 8# 4# 6# (Trunk)# 2# (0-2)#
Description
Use this address to enable trunks for DID or DNIS calls.
•
If DID is selected,
the system will use the DID Numbers Table (see FF1
8# 3#) to determine which extension(s) will receive the DID call.
•
If DNIS is selected (available only with T1 interface),
the system will
use the DNIS Numbers Table (see FF1 8# 4# 7#) to determine which
extension(s) will receive the DNIS call.
The DID Numbers Table can be used for DID or DNIS. Therefore, if all 500
entries in the DNIS Numbers Table are filled, a T1 channel can be set to DID,
and DNIS service can still be used.
Programming
Related Programming
Inbound DID Dial Numbers: FF1 8# 3# (DIDNo.)# (ExtNo.)#
DNIS Number Setting: FF1 8# 4# 7# (DNISNo.)# (ExtNo.)#
DID/DNIS Flexible Ringing Assignments: FF1 8# (5# or 6#) (DID/DNIS
No.)# (ExtNo.)# (0000[00]-1111[11])#
Notes
Digit Length Requirement.
The DBS only supports 4-digit DID/DNIS
numbers.
CO Requirement.
When the CO sends a DID/DNIS call to the DBS, it first
receives a “wink” signal from the DBS before sending the digits. Once the
wink is received, the CO should wait at least 200 ms before sending the
digits.
Power-Cycling Requirement.
For changes to this parameter to take effect,
the system must be turned off, then back on.
FF1 8# 4# 6# (1-64)# 2# (0-2)#
Trunk Number (1-64)
0=Neither DID nor DNIS
is used.
1=DID is used.
2=DNIS is used.
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...