Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-204
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Programming
Related Programming
Trunk Configuration: FF1 8# 4# (4 or 5)# 1# 1# (0 or 1)#
Number of T1 Channels: FF1 8# 4# (4 or 5)# 1# 2# (0-24)#
Trunk Circuit Type: FF2 (Trunk)# 21# (0-3)#
Notes
Loop-Start Card Version Requirement.
This
T1 Trunk Closure
address
can only be used with the VB-43510A or VB-43511A versions of the loop-
start card.
CPC-B Versions Beginning With 6.03.
The
T1 Trunk Closure
address is
no longer present. Instead, simply use the
Trunk Circuit Type
address (FF2
Trunk# 21#) to assign trunk ports as Loop Start, Ground Start, DID or T1.
FF1 8# 7# (1 or 2)# (1-4)# (1-8)# (0 or 1)#
1=Master Cabinet Trunk Slot Trunk Port
2=Slave Cabinet on Card
1=Close
0=Open