Offhook Signal Volume
Software Version: All Versions
Address: FF3 (ExtPort)# 15# (0-4)#
Description
The volume for offhook signaling can be set to one of five different levels.
Offhook signaling is a “beep-beep” tone heard every 6 seconds in the receiver
of an offhook extension (already engaged in a call), indicating another trunk
call is coming in.
The next address (
“Offhook Signal Pattern”
) allows you to set the tone
signal to be sent repeatedly, or only once, to an offhook extension user.
Programming
Related Programming
Alert Tone for Busy Override & OHVA: FF1 2# 1# 17# (0 or 1)#
Offhook Signal: FF3 (ExtPort)# 7# (0 or 1)#
Offhook Signal Pattern: FF3 (ExtPort)# 16# (0 or 1)#
Notes
Reset Requirement.
If you change the volume level in this address, the
extension phone must be unplugged, then plugged back in so that the change
will take effect.
FF3 (1-144)# 15# (0-4)#
Extension Port
Volume Level
0=lowest level (quietest)
1=next lowest level
2=mid-level
3=next highest level
4=highest level (loudest)