Appendix C. EX 1.0 Feature Update
Section 400-Programming
Page C-44
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Hardware Requirements
• A printer or external call accounting system is required to receive SMDR
data.
Considerations
• Unlike other CPC circuit cards, the CPC-EX supports two serial ports.
Serial Port 1 is labeled
CN4
and is located on the backplane. Serial Port 2
is labeled
CN5
and is located on the front of the CPC-EX card. Serial Port
2 requires a special interface cable.
• Be sure to select the correct port to output SMDR data. From the
Attendant’s phone:
-
dial
#90
to set Serial Port 1 (the backplane port) to output Bus
Monitor/Maintenance and Serial Port 2 to no output.
- dial
#92
to set Serial Port 1 to output SMDR and Serial Port 2
to output Bus Monitor/Maintenance data.
- dial
#93
to set Serial Port 1 to output SMDR data and Serial
Port 2 to no output.
Modification to T1 Signaling Types
Description
The default values for T1 Incoming and Outgoing Signal Types have been
changed to set “Wink Start” as the default. This will allow easier
programming of E&M trunks.
Outgoing Signaling Type
Programming
FF1 8# 4# 6# (1-64)# 3# (0-2)#
0=Immediate Start
Trunk Number (1-64)
1=Wink Start
2=Dial Tone Start
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...