6-40
DBS 576HD (USA) issued September 2001
576-50-700
Chapter 7. SLT Features
Section 700 - Operation
•
FF1-2: Dial Plan
Considerations
•
The second extension called using the Reset Call feature must have the same number of digits as
the first extension.
•
If you program the System for Reset Call, the following features are not available: Camp-on
(Ext. no. + 2), Callback Request (Ext. no. + 3), Message Waiting (Ext. no. + 4, Ext. no. + 5),
Intercom Busy Override (Ext. no. + 9).
Room Monitoring
Version 3.5 and higher
Description
This feature allows the user to monitor the sounds in a room from another extension or room. The
transmitter in the telephone handset is used as a remote “microphone” for monitoring these sounds.
To activate this feature, the monitored extension must enable the Room Monitor feature before the
monitoring extension can listen to the sounds in the room. The monitored extension can be enabled
using an SLT, DSLT, or Key Telephone. No special programming is required to allow an extension to
enable the monitored mode.
Operation
To set up the monitored extension:
When a monitored extension receives a call, the caller hears a busy tone. Additional operations may
be performed from the monitored extension when it is in monitored mode:
Action
Result
1. Dial the monitored extension access code (
default 775
),
OR...
Note:
The handset must be off-hook to activate the
Room Monitor feature.
You will hear a confirmation tone after
the monitored extension has enabled the
Room Monitor feature. (If the monitored
extension has an LCD display, a confir-
mation message will also be shown.)
Press an FF key assigned with the monitored access code
Action
Result
1. Placing the handset back On Hook or pressing ON/OFF
Monitored mode is cancelled. Extension
returns to idle.
2. Pressing digits 0-9, *, #, HOLD, PROG, CONF, AUTO,
REDIAL, MSG, FF Key,
No response is given. Extension remains
in monitored mode.
3. Flash
Monitored mode is cancelled. Dial tone is
returned to handset.