Section 700 - Operation
Chapter 7. SLT Features
576-50-700
DBS 576HD (USA) issued September 2001
3-27
operate in the automatic mode for those days. The System will stay in the same mode for the period.
The mode may be manually changed at any time.
For instance, the System can be set to automatically enter Day 1 mode at 8:00 a.m. on weekdays and
enter Night mode at 5:00 p.m. on weekdays. All incoming calls, TRS and attendant group handling
would change accordingly. On Saturday and Sunday, the System would stay in Night mode.
The Automatic Day/Night modes may be set in User Maintenance. See “Set Mode Schedule” on
page 4-15, “Set Special Day Mode” on page 4-24, “Set Exception Day Mode” on page 4-11, and “Set
Day of Week Mode” on page 4-9.
Hardware Requirements
•
N/A
Related Programming
•
N/A
Considerations
•
You can only set Automatic Day/Night modes on a system-wide basis. If tenant groups require
separate Day/Night modes, you must set these modes manually.
•
You can manually override Automatic Day/Night modes. (See “Manual Day/Night Mode” on
page 3-24.)
Digital Pad
Description
Digital pad settings allow adjustment of call levels for different call types. There are 29 pad classes in
the System. For pad class, a volume adjustment is assigned for a connection to any pad class
assignment. The volume adjustment is between -30dB and +30 dB.
There are 8 extension pad classes and 16 trunk pad classes. In addition, there are pad classes for
conference calls, page port, MFR, RAI Modem, and Conference Call Unit. One pad class is currently
not used.
For instance, a call from an extension assigned to extension pad class 1 to a trunk assigned to trunk
pad class 3 would received the volume adjustment assigned to this connection combination.
Hardware Requirements
•
N/A
Related Programming
•
N/A
Considerations
•
N/A