(2) If abnormalities as mentioned below are found during use, please do not use the Unit and contact your authorized dealer
immediately.
1)
Water leakage.
2)
No water flow.
3)
Water temperature cannot be controlled.
4)
ELB lamp does not light up.
(3) Special skill is required for repairing. Never try to repair the Unit by yourself.
(1) Check the following points before asking for repair.
③
Clean the Filter Unit.
Please make sure the O Ring is not removed and shall be free from
foreign particle to avoid water leaking.
CAUTION
④
Insert the Filter Unit and tighten it properly (clockwise).
⑤
Turn the Water Volume Knob to its original position
base on Water Flow Rate Adjustment at page 16.
Symptom
Points to be checked
1. Check the Filter Unit. Clean the Filter if it is clogged by stain and dirt (refer Filter Unit Cleaning as above).
2. Check the Shower Head and Shower Plate. Clean the Shower Head and Shower
Plate if it is clogged by dirt (refer Shower Head Cleaning at page 16).
1. Make sure the Push On-Off Lever is at “On” position.
2. Make sure the ELB Reset Lever is not slide down.
Push up the ELB Reset Lever to reset the ELB (see TEST OPERATION at page 21).
3. Make sure to switch on the ON/OFF DP (double pole) Switch.
4. Make sure to switch on the Miniature Circuit Breaker (MCB).
1. Check the Main Water Valve. Turn “On” the Main Water Valve if it is closed (refer HOW TO USE at page 15).
2. Check the ELB Lamp (Red) indication.
• Red lamp light “Off”. Check the Push On-Off Lever, if the red lamp still light “Off”.
please do not use the unit and contact the authorized dealer immediately.
1. Check the WATER FLOW RATE ADJUSTMENT as in page 16.
Water is not drawn normally.
No hot water comes out from
the outlet
(no electric supply to the unit)
No water flows out from the
Shower Head at all.
Water not hot enough.
240 V a.c. 50 Hz
3600 W
Inlet Water Temp. (OFF), 1000 W ~ 3600 W
9.8 kPa / 0.1 k
g
f/cm² / 1.42 psi
380 kPa / 3.87 k
g
f/cm² / 55 psi
420(H) mm x 185(W) mm x 85(D) mm
Single Point System (Open Outlet)
DH-3MS1
1.6 k
g
DH-3MT1
1.7 k
g
Model
Voltage
Power Consumption
Electric Power Control
Min. Water Pressure
Max. Water Pressure
Dimension
Weight
Outlet System
5. SPECIFICATION
4. TROUBLESHOOTING
Filter Unit
O P
EN
CLO
SE
FILTER
CLEANING
O Ring