16
3.
Error Code List
The error code consists of 8 bits data and it shows the following information.
Attribute
Main item
Sub item
Error code
Contents (Upper)
Error Indication
High
4bits
Low
4bits
Check point (Lower)
Detecting
device
Part/Circuit
LENS
Lens drive
Focus
18*0
0?01
HP Low detect error
(Focus encoder always detects High, and not becomes
Low)
FOCUS L
LENS FPC/
DSP
Mechanical lock, FP9004-(35) signal line or IC6001
(VENUS ENGINE)
0?02
HP High detect error
(Focus encoder always detects Low, and not becomes
High)
FOCUS H
Mechanical lock, FP9004-(35) signal line or IC6001
(VENUS ENGINE)
Zoom
0?10
Collapsible barrel Low detect error
(Collapsible barrel encoder always detects Low.)
ZOOM L
ZOOMm/
LENSu
Mechanical lock, FP9004-(24) signal line or IC6001
(VENUS ENGINE)
0?20
Collapsible barrel High detect error
(Collapsible barrel encoder always detects High.)
ZOOM H
Mechanical lock, FP9004-(24) signal line or IC6001
(VENUS ENGINE)
0?30
Zoom motor sensor error (Initialized or Terminated)
ZOOM ENC
Mechanical lock, FP9004-(38), (40) signal line or IC6001
(VENUS ENGINE)
0?40
Zoom motor sensor error (During monitor mode.)
Mechanical lock, FP9004-(38), (40) signal line or IC6001
(VENUS ENGINE)
0?50
Zoom motor sensor error (During monitor mode with slow
speed.)
Mechanical lock, FP9004-(38), (40) signal line or IC6001
(VENUS ENGINE)
0?60
Detection of zoom misregistration by impact such as fails
(No indication) (No indication)
Lens Unit
OIS
1000
PSD (X) error. Hall element (X axis) position detect error in
OIS unit
OIS X
LENSu NG
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect error in
OIS unit
OIS Y
OIS Unit
3000
GYRO (X) error. Gyro (IC7101: X axis) detect error on
Main P.C.B.
GYRO X
GYRO NG
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
4000
GYRO (Y) error. Gyro (IC7101: Y axis) detect error on
Main P.C.B.
GYRO Y
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
5000
GYRO (R) error. Gyro (IC7101: R axis) detect error on
Main P.C.B.
GYRO R
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
6000
Drive voltage (X) error
OISX REF
LENSu/LENS
FPC
LENS Unit, LENS flex breaks, IC6001(VENUS ENGINE)
AD value error, etc.
7000
Drive voltage (Y) error
OISY REF
LENS Unit, LENS flex breaks, IC6001(VENUS ENGINE)
AD value error, etc.
8000
OIS GYRO - Digital communication error
(No indication) (No indication)
IC7101 (Gyro element) or IC6001 (VENUS ENGINE)
Lens
10*3
0000
Lens cap error
(No indication) (No indication)
Zoom motor, Zoom pulse encoder 1, 2
10*4
0000
Lens cap error (During monitor mode)
Zoom motor, Zoom pulse encoder 1, 2
10*8
0000
Lens cap error (During monitor mode with slow speed)
Zoom motor, Zoom pulse encoder 1, 2
18*1
0000
Power ON time out error
LENS DRV
LENSu
Lens drive system
18*2
0000
Power OFF time out error
Lens drive system
Summary of Contents for DMC-FZ70GC
Page 21: ...21 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 P C B Location ...
Page 23: ...23 Fig D2 8 3 2 Removal of the Main P C B Fig D3 Fig D4 ...
Page 25: ...25 8 3 5 Removal of the Lens Unit Fig D7 8 3 6 Removal of the LCD Unit Fig D8 ...
Page 26: ...26 8 3 7 Removal of the Flash P C B Fig D9 Fig D10 ...
Page 28: ...28 Fig D13 Fig D14 ...