18
5.2.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
No.
Parts No.
Connection
From
1
VFK1175
FP9001(MAIN) - REAR OPERATION UNIT
16PIN 0.5FFC
2
VFK1364
FP9002(MAIN) - MOUNT BOX UNIT(SHUTTER)
14PIN 0.5FFC
3
VFK1284
FP9003(MAIN) - TOP CASE (R) UNIT(HOT SHOE FPC)
24PIN 0.5FFC
4
RFKZ0477
FP9004(MAIN) - LVF UNIT
45PIN 0.3FFC
5
VFK1175
FP9007(MAIN) - TOP OPERATION (L) UNIT
16PIN 0.5FFC
6
RFKZ0393
FP9009(MAIN) - FP7350(REMOTE)
15PIN to 10PIN 0.3FFC
7
VFK2024
FP9010(MAIN) - FP1001(POW FLASH)
51PIN 0.3FFC
8
VFK1480
FP9011(MAIN) - OPTICAL SENSOR UNIT
6PIN 0.5FFC
9
VFK1951
FP9090(MAIN) - LCD UNIT
39PIN 0.3FFC
10
RFKZ0477
FP3901(MAIN) - MOUNT BOX UNIT(SENSOR)
45PIN 0.3FFC
11
RFKZ0477
FP3902(MAIN) - MOUNT BOX UNIT(SENSOR)
45PIN 0.3FFC
12
RFKZ0477
FP3903(MAIN) - MOUNT BOX UNIT(SENSOR)
45PIN 0.3FFC
13
RFKZ0477
FP3904(MAIN) - MOUNT BOX UNIT(SENSOR)
45PIN 0.3FFC
14
RFKZ0564
FP9008(MAIN) - MOUNT BOX UNIT(LENS I/F)
23PIN 0.3FFC
15
RFKZ0359
P9002(MAIN) - MOUNT BOX UNIT(SSWF)
2PIN CONNECTOR
16
RFKZ0359
P8503(POW FLASH) - FLASH UNIT
2PIN CONNECTOR
17
VFK1576DC202
P8504(POW FLASH) - FLASH UNIT
2PIN CONNECTOR
18
VFK1576DC202
P9005(MAIN) - HINGE SW P.C.B.
2PIN CONNECTOR
Summary of Contents for DMC-G2EB
Page 16: ...16 4 Specifications ...
Page 36: ...S 15 ...
Page 50: ...S 29 ...
Page 69: ...S 48 ...
Page 77: ...S7 Exploded View S7 1 Camera Lens Unit 1 S 56 200 ...