HDD READ SEEK
Inspection
Inspecting seek time of HSS to inspect perfor-
mance.
At start
The [*] sign is added every 20 sec-
onds while inspecting.
Two digits on the right side are the
progress level of the inspection
(The unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o )
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.)
$: [X] is displayed when seek time is
over 270msec., there is error or
transfer rate is NG.
Position at $ is space when exclud-
ing those.
##: Number of data of over
100msec. and less than 270msec.
When it is over 100, [99] is dis-
played.
When the number is less than 5, we
judge it normal.
Press [3] [1] in service mode.
* When canceling the inspection
mode while executing, do “forced
power-off”.
Method:
Press [POWER] key more than 4
seconds.
Item
FL display
Key operation
Mode name
Description
(Remote controller key)
Summary of Contents for DMR-EH49ECA
Page 5: ...5 2 2 Precaution of Laser Diode ...
Page 8: ...8 3 3 Caution for DivX ...
Page 10: ...10 4 Specifications ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 14: ...14 ...
Page 40: ...40 10 1 2 Checking and Repairing of RAM Digital P C B Module ...
Page 41: ...41 10 1 3 Checking and Repairing of Main P C B ...
Page 42: ...42 10 1 4 Checking and Repairing of HDD ...
Page 43: ...43 10 2 Caution for Replacing Parts 10 2 1 Items that should be done after replacing parts ...
Page 56: ...S 11 ...
Page 70: ...S 25 ...
Page 80: ...S 35 ...
Page 85: ...S 40 ...