8 Service Explorer
Confirm “RAM-Drive Last Error” in Service Mode
Execute Service Mode
1. Press [REC], [CH UP] and [OPEN/CLOSE] simultaneously for 5 seconds when P-off.
FL Display:
*After finishing display “(7). Factor of Drive Error occurring”, press [0] [2] ~[1] [9] keys of the Remote Controller so that
19 memories can be displayed as maximum.
2. Press [4] [2] keys of remote controller.
Example of FL Display:
(1) Error Number is displayed for 5 seconds.
(2) Time when the error has occurred is displayed for 5 seconds.
(3) Last Drive Error (1/2) is displayed for 5 seconds.
(4) Last Drive Error (2/2) is displayed for 5 seconds.
10
DMR-ES20EG / DMR-ES20EP / DMR-ES20EE
Summary of Contents for DMR-ES20EG
Page 2: ...2 DMR ES20EG DMR ES20EP DMR ES20EE ...
Page 7: ...5 Each Button 7 DMR ES20EG DMR ES20EP DMR ES20EE ...
Page 12: ...Error Occurring Disc State 12 DMR ES20EG DMR ES20EP DMR ES20EE ...
Page 25: ...12 2 Checking and Repairing of Digital P C B 25 DMR ES20EG DMR ES20EP DMR ES20EE ...
Page 26: ...12 3 Checking and Repairing of Main P C B 26 DMR ES20EG DMR ES20EP DMR ES20EE ...
Page 27: ...12 4 Checking and Repairing of DVD RAM Drive 27 DMR ES20EG DMR ES20EP DMR ES20EE ...
Page 36: ...DMR ES20EG DMR ES20EP DMR ES20EE 36 ...
Page 42: ...DMR ES20EG DMR ES20EP DMR ES20EE 42 ...
Page 54: ...DMR ES20EG DMR ES20EP DMR ES20EE 54 ...
Page 63: ...20 Exploded Views 20 1 Casing Parts Mechanism Section 63 DMR ES20EG DMR ES20EP DMR ES20EE ...
Page 64: ...20 2 Packing Accessories Section 64 DMR ES20EG DMR ES20EP DMR ES20EE ...