Both the Error numbers and its supplementary data of history 1, 2and 3 are indicated by selecting the Service mode 3, 4 and 5 as shown
above.
In case of that any Error has not been memorized, the Error number and its supplementary data is indicated as " - ".
8.2.4.4. (VHS) Display of Supplementary Data 3 and 4
During displaying the Self-Diagnosis History, press [STOP] key on front panel to change the display.
*Example of Display
A: Service Mode Number.
B: Supplementary Data 3...Mechanism process shifting Number.
C: Supplementary Data 4...LM(Loading Motor information)
*Display of
means that " Loading Motor turns ON when [EJECT] button was pressed, but an
error has occurred while mechanism was between REV position and LOAD position.
<Supplementary Data 3>