Item
FL display
Key operation
Mode name
Description
(Remote controller key)
HDD
READ
SEEK
Inspection
Inspecting seek time of HSS to inspect
performance.
At start
The [*] sign is added every 20
seconds while inspecting.
Two digits on the right side are the
progress level of the inspection
(The unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o )
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.
)
$: [X] is displayed when seek time is
over 270msec., there is error or
transfer rate is NG.
Position at $ is space when
excluding those.
##: Number of data
of over
100msec. and less than 270msec.
When it is over 100, [99] is
displayed.
When the number is less than 5, we
judge it normal.
Press [3] [1] in service mode.
* When canceling the inspection
mode while executing, do “forced
power-off”.
Method:
Press [POWER] key more than 10
seconds.
21
DMR-EX77EG / DMR-EX77EC / DMR-EX77EC1 / DMR-EX77EB / DMR-EX87EG / DMR-EX87EC / DMR-EX87EC1 / DMR-EX87EB