130
Error messages
(continued)
Error messages (continued)
If the error message display persists even after the
VTR has been shut down and started up again,
consult your dealer.
Display
z
Description
z
VTR operation and remedial action
E-51
FRONT LOAD
ERROR
If the take-up reel has turned without engaging
the tape for a specific period of time during the
tape start or end processing operation while
loading is being performed (at the half position),
the AUTO OFF lamp lights, and the message
display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-52
W-UP REEL
NOT ROTA
If, after the cassette has been inserted, the tape
take-up reel has not wound up the tape while the
total tape amount is not detected and while the
tape is traveling, the AUTO OFF lamp lights, and
the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-53
WINDUP
ERROR
If, after the total tape amount has been detected,
the amount of tape wound up onto the take-up
reel and the amount of tape supplied by the
supply reel differ to an abnormal extent while the
tape is traveling, the AUTO OFF lamp lights, and
the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-55
UNLOAD
ERROR
If the tape has not been wound up during
unloading, the AUTO OFF lamp lights, and the
message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-57
S-FF/REW
TIMEOVER
When the tape start or end processing operation is
not completed, the AUTO OFF lamp lights, and the
message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-59
DRUM ROTA
TOO SLOW
If the rotational speed of the cylinder motor is
abnormally slow, the AUTO OFF lamp lights, and
the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-60
DRUM ROTA
TOO FAST
If the rotational speed of the cylinder motor is
abnormally high, the AUTO OFF lamp lights, and
the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-61
CAP ROTA
TOO SLOW
If the rotational speed of the cylinder motor is
abnormally slow, the AUTO OFF lamp lights, and
the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-64
S REEL ROTA
TOO FAST
If the supply reel motor rotates at an abnormally
fast rate, the AUTO OFF lamp lights, and the
message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-67
T REEL ROTA
TOO FAST
If the take-up reel motor rotates at an abnormally
fast rate, the AUTO OFF lamp lights, and the
message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
Display
z
Description
z
VTR operation and remedial action
E-69
T REEL
TORQUE ERR
If an abnormal torque applied to the supply reel
motor is detected or if an abnormal current flowing
to the current-sensing resistor is detected, the
AUTO OFF lamp lights, and the message display
blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-70
S REEL
TORQUE ERR
When the tape start or end processing operation is
not completed, the AUTO OFF lamp lights, and the
message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-71
CAP TENSION
ERROR
If an abnormal tension is detected at the supply
side in the capstan mode, the AUTO OFF lamp
lights, and the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-72
REEL
TENSION
ERROR
If an abnormal tension at the supply side is
detected in the reel mode, the AUTO OFF lamp
lights, and the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-73
REEL DIR
UNMATCH
If the take-up reel motor is running in the reverse
direction, the AUTO OFF lamp lights, and the
message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-74
DRUM
TORQUE
ERROR
If excess torque being applied to the cylinder motor
is detected, this error number flashes on the
display.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.
E-FF
If the tape start and tape end are detected at the
same time either during or after loading, the AUTO
OFF lamp lights, and the message display blinks.
VTR:
Stops.
z
Set the POWER switch to OFF and then back to
ON again.