TEST AND MEASUREMENT
MCUK000601C8
Section 6
Issue 1
Service Manual
– 39 –
Revision 0
Figure 6.11: PC Screen (SCRN9)
3.
On the PC, select NORMAL MODE and press ENTER.
4.
Press F10 on the PC.
5.
After approximately 1 second, set the interface cable switch to ON (position is marked by a dot).
Entering Call Mode from Test Mode
Ensure that a fully-charged battery is attached to the telephone.
The screen of the PC should resemble the one shown below:
Figure 6.12: PC Screen (SCRN11)
1.
At the PC, change the SOFT SIM field to read <ENABLE>. Press ENTER.
2.
At the PC, change the TEST MODE field to read <TERM>. Press ENTER.
The UUT will power down and up again. If the UUT is connected to a GSM test set,after a delay of approximately five
seconds, the UUT will register service.
3.
To return to test mode, set the SOFT SIM field to <DISABLE> and set the TEST MODE field to <TEST>. Press Enter.