ADJUSTMENT PROCEDURES
Issue 1
Section 7
MCUK010801C8
Revision 0
– 38 –
Service Manual
7.2.2.
GSM 1800
7.2.3
Power Level Calibration
1.
Power on the telephone in Test Set Mode.
2.
Scroll down the menu until CHANGE CH <62> is highlighted and then press ENTER.
3.
Scroll down the menu until PL <5> is highlighted. Use the left and right cursor keys to select <14>. Press ENTER.
4.
Scroll down the menu until TX DATA <OFF> is highlighted. Using the left / right cursor keys, highlight <NRL R> and press
ENTER.
5.
At the power meter, measure the peak power.
6.
If measured power is in the range of the target power, then proceed to step 10.
Power Level
(PL)
Output Power (dBm)
Change / dB
Nominal
Target
Spec
Min
Max
Min
Max
0
29.05
28.8
29.3
28.8
29.3
3
1
27.8
27.3
28.3
27.0
28.8
3.5
2
26
25.5
26.5
25
27
4
3
24
23.5
24.5
23
25
4.5
4
22
21.5
22.5
21
23
4.5
5
20
19.5
20.5
19
21
4.5
6
1817.5
18
.5
17
19
4
7
16
15.5
16.5
15
17
4
814
13.5
14.5
13
15
4
9
12
11.5
12.5
11
13
4
10
10
9.5
10.5
9
11
4
11
87.5
8
.5
7
9
4
12
6
5.5
6.5
5
7
4
13
4
3.5
4.5
3
5
4
14
2
1.5
2.5
1
3
4
15
0
-0.5
0.5
-1
1
4
NOTE:
To ensure that the telephone operates within set SAR margins, Panasonic recommends that a power meter
capable of measurement to an accuracy of ±0.2 dB is used when calibrating power levels. Use of a less
accurate power meter may result in the telephone failing to meet SAR standards.
Summary of Contents for EB-GD95
Page 64: ...LAYOUT DIAGRAMS MCUK010801C8 Section 9 Issue 1 Service Manual 60 Revision 0 D C E A B F 3 4 ...
Page 66: ...CIRCUIT DIAGRAMS on 9 Issue 1 Revision 0 GD95 Circuit Diagram Logic A4 A4 ...
Page 67: ...CIRCUIT DIAGRAMS Issue 1 Section 9 Revision 0 58 Figure 9 2 GD95 Cir A4 A4 ...
Page 68: ...9 MCUK010801C8 Service Manual GD95 Circuit Diagram RF A4 A4 EB GD95 EBGD95C ...