ADJUSTMENT PROCEDURES
Issue 1
Section 7
MCUK010801C8
Revision 0
– 50 –
Service Manual
2.
If this value is outside the range 161 - 281, then there is a fault and further investigation is required. Otherwise, calculate
the difference between the recorded value and the theoretical value of 161. Record this value for use later.
3.
Press F6 and select TRIM OTHER. Select COMP OFFSET and enter the value recorded in step 2.
4.
Press F9. Wait for the prompt “Saving EV Trim data” to disappear, turn OFF the power supplies and disconnect the