Disable / re-enable routing equipment
(H2/B9)
Disabled outputs are listed in menu H4/U1 from which it is possible to
get a print-out.
Outputs for routing equipment (fire brigade tx / fault tx) can be
disabled and re-enabled via this menu. Can be useful during an
installation and test period, when only local alarms are required.
Disabled output is indicated by LEDs
Fault /
Disablements
"General
disablements" (L10) and "Fire brigade tx" (L12).
Disabled output will stay disabled until re-enabled again via this
menu.
Action
Text in display
Comments
"Menu"
According to chapter
"Access", see page 85.
Scroll to menu H2.
H2 Disable or re-enable
"
↵
"
B1 Disable zone
B2 Disable zone / address
B3 Disable output
B4 Re-enable zone
B5 Re-enable zone / address
B6 Re-enable output
B7 Disable / re-enable output type
B8 Disable / re-enable alarm devices
B9 Disable / re-enable routing equipment
B10 De-activate alert annunciation function
Scroll to menu B9.
B9 Disable/Re-enable routing equipment
"
↵
"
Routing equipment for
Fire
Fault
Fire and fault
[Blank space]
Escape
menu
Disable
Re-enable
Use "▼" or "▲" to select
output type(s).
Press "Disable" or "Re-
enable”.
"Disable" or "Re-
enable"
Routing equipment for
Fire
Fault
Fire and fault
[Blank space]
Escape
menu
Disable
Re-enable
Disable or Re-enable
another output type or
press "
ESC
". Scroll to
another menu or press
"
ESC
".