Fire alarm system 

EBL512

 

________________________________________________________________________ 

Panasonic Electric Works 

2008-08-20                          Fire & Security Technology Europe AB                         Page 3 of 6 

  The inter activity function is 

using information from one, two 
or a larger number of detectors 
in the system to provide a more 
secure detection of a real fire. 

  A family of state of the art 

analog detectors gives the c.i.e. 
accurate and noise free 
information about occurrence of 
smoke and/or temperature 
changes in the installation. 

 

  

 

 

The analog detector types 33xx (left) received 
a design award at the 1998 Hanover Exhibition. 

 

The newer analog detector types 43xx (right) 
have an even more attractive & slender design. 

 
A large variety of units can be 
connected to the four COM loops: 

 Analog 

detectors 

 Conventional 

detectors 

  Intrinsically Safe (IS) detectors 

  Water proof heat detectors 

  Addressable manual call points 

  Addressable short circuit iso-

lators 

  Addressable I/O units (inputs / 

supervised voltage outputs as 
well as relay outputs) 

  Addressable sirens / sounder 

bases 

 

The EL512 fire alarm system has 
a set of functions that meets the 
most stringent requirements 
relating to fire detection, fire 
presentation and measures.  

 

  Service signal is given when a 

detector is contaminated to a 
certain level.  

 A large number of alarm 

algorithms is supported by the 
system and can be set for each 
analog detector individually. 

  Alert annunciation.  The output 

for the alarm transmitter can be 
delayed for immediate on site 
investigation of a fire alarm. 

 Individual detectors, zones, 

programmable outputs and 
outputs for the alarm transmitter 
can be individually disabled. 

 

Internally and/or externally 
controlled time channels.  E.g. 
one or more alarm points may 
be disabled via a time channel. 

  Outputs can be programmed in 

a very flexible way enabling 
control of sirens, fire doors, 
extinguishing systems etc. 

  External Fire brigade panels 

can be connected to each c.i.e. 

 Presentation of the actual 

system status in a PC or 
Pocket-PC via the 

Web-server

 

II

 connected to an intranet 

(LAN) or Internet.  Remote 
control with encrypted and safe 
two-way communication.  In 
case of fire alarm, service signal 
etc. e-mails can be sent to the 
adequate personnel.  Provides 
also one-way communication to 
an external computer system. 

 The 

Web-server II

 (the HW) 

can be used with the OPC512 
SW and connected to a PC with 
Panasonic FP OPC Server SW 
for a reliable connection to your 
industrial applications (clients).   

 

The TLON Network 

Up to 30 nodes (i.e. EBL512 c.i.e:s) 
can be connected to a TLON 
Network.  One of the nodes can be 
an external PC with a software 
driver for a Security Management 
system, which gives full control of 
and access to all data in all 
EBL512 connected to the network. 
 
 
 

Summary of Contents for EBL512

Page 1: ..._____________________________________ Panasonic Electric Works 2008 08 20 Fire Security Technology Europe AB Page 1 of 6 Fire alarm system EBL512 An analog addressable fire alarm system for early detection without unwanted alarms www panasonic fire security com ...

Page 2: ... Power Supply The c i e can on four COM loops handle up to 512 input and or output units i e detectors manual call points general in and output units for free programmable user definable functions etc Each loop unit uses one address Conventional detectors can also be used in the system Control and Indication Equipment EBL512 EBL512 can work as a standalone unit or in a TLON network with up to 30 u...

Page 3: ...a certain level A large number of alarm algorithms is supported by the system and can be set for each analog detector individually Alert annunciation The output for the alarm transmitter can be delayed for immediate on site investigation of a fire alarm Individual detectors zones programmable outputs and outputs for the alarm transmitter can be individually disabled Internally and or externally co...

Page 4: ...e data can also be uploaded from the c i e Win512 is also used to download new software etc System overview C i e 1548 1826 Ext FBP 1828 Ext FBP 1735 36 AA unit 1728 EPU 4301 Analog photoelectric smoke detector 3333 3339 Addr Manual Call Point TLON Network 1590 board 1590 board 1590 board 1580 board 0 7 1587 board COM loop External PC system Web browser LAN or Internet 4300 Analog multi detector 3...

Page 5: ...ctors Fast connectors Ext LED output 4300 Analog multi detector 4301 Analog photoelectric smoke detector 4313 Analog base with isolator For analog detectors Detector to be plugged in Analog base 3312 or 4313 Conventional Detectors connected to a COM loop via a zone line input e g 3361 2324 Base For conventional detectors 4318 Combination heat detector 59 degrees rate of rise 4350 Multi detector 43...

Page 6: ..._____________________________________________ Panasonic Electric Works Fire Security Technology Europe AB Citadellsvägen 23 SE 211 18 Malmö Sweden Tel 46 0 40 697 70 00 Fax 46 0 40 697 70 99 info fste eu pewg panasonic com www panasonic fire security com ...

Reviews: