background image

INSTRUCTION MANUAL

Static Remover & Dust Remover Pulse Air-gun Ionizer

EC-G02

MJE-ECG02 No.0048-24V

Thank you very much for purchasing Panasonic products. Read this Instruction Man-

ual carefully and thoroughly for the correct and optimum use of this product. Kindly 

keep this manual in a convenient place for quick reference.

WARNING

 

Never use this product with a device for personnel protection.

 

In case of using devices for personnel protection, use products which meet laws

or standards, such as OSHA, ANSI or IEC etc., for personnel protection applica-

ble in each region or country.

 

● Do not use this product in places where there may be a danger of flammable or 

combustible items being present.

 

Clean the discharge needle regularly (about once a week), otherwise optimum

charge removal performance may not be obtained and fire or operating problems  

may occur.

 

 High voltages are applied to the discharge needle, so never touch the discharge

needle while the power for the product is turned on, otherwise electric shocks

may result.

 

If this product is used in an airtight room, ozone emitted from this product may

be detrimental. Therefore, in order for this product to be used in an airtight room, 

be sure to keep the room ventilated.

 

Do not direct ionized air toward the face. Ozone may cause irritation to places

such as the nose and throat. 

 

Do not look directly into the white LED spotlight. It may cause injury to the eyes.

 

● Since the tip of the discharge needle is sharp, take sufficient care in handling the 

discharge needle, or injuries may result.

 

When air is not being supplied to this product, turn off the power in order to stop

discharging from occurring. If discharging is allowed to continue while air is not

being supplied, the ozone concentration will rise and accidents or operating

problems may occur.

 

 This product includes precision components, so do not drop it or hit it against

other objects. If this is not observed, accidents or problems with operation may

occur.

1

OUTLINE

 

This product is an air gun-type electrostatic charge removal and dust removal de-

vice which uses ion generation from corona discharges.

 

This product is equipped with a pulse ionized air emission function for effectively

removing dust and which can be replaced with normal continuous ionized air

emission.

 

It uses a built-in high-illumination white LED spotlight in order to illuminate the di-

rection in which ionized air is being blown.

2

PART DESCRIPTION

Nozzle guard

White LED

Mode select switches

Upper: Pulse air mode selection

Lower: LED illumination mode selection

M3×10 mounting screw

Fixed metal hook

Back cover

Trigger

Cable connector

ø8mm air tube

Straight joint

Solenoid valve 

indicator

M3×10 mounting screw

(Tapping screw)

3

I/O circuit DIAGRAM

D

Main circuit

AC adapter (accessory)

24V

0V

5V

4.7kΩ

External input

Switch for external input

Nozzle

COM (-)

[connected internally to 0V,COM (-) and 

nozzle metallic parts]

GND

D: Power supply reverse connection 

protection diode

Internal circuit

Users’ circuit

100 to 240V AC

 

Pin layout for AC adapter power

supply connector

(From cable insertion side)

 

Terminal block diagram

Terminal No.

Terminal name

1

0V

2

COM (-)

3

External input

4

N.C. (not used)

5

24V

6

N.C. (not used)

7

N.C. (not used)

8

GND

 

1 and 5 are connected to the AC adapter.

 

Use the accessory connector wiring terminal to connect external input or GND.

When using external input

When using external input, ionized air discharging can be carried out using the

same ON/OFF operations as trigger input.

Note:  The COM (-) terminal which uses external input is connected internally to 0V, the GND terminal and the nozzle 

metallic parts. If external input ON/OFF switching is carried out using an external control device instead of an in-

dependent mechanical-type switch, or if the 0V potential of the external control device and the grounding poten-

tial of the place of use are different (such as in the case of positive power supply grounding), the external control 

device used for external input should have an insulated on/off procedure for the 0V line (such as photocoupler 

output or relay output) in order to prevent short-circuits from occurring.

4

WIRING / PIPING

 

Use the accessory relay cable to connect the main unit and the AC adapter.

 

Use the accessory straight joint to connect a suitable air tube to the main unit.

 

Connect the GND terminal of this product to a secure ground when using it.

 

Since the pressure will drop when the air piping from the main pressure supply is

extended or pneumatie-components (e.g., needle valve, speed-controler, minifil

-

ter) are added, keep an eye on the pressure supply to the ionizer maiking sure it

isn’t in short supply. For the pneumatic-components, select those that can accom-

modate the air supply flow rate.

The air supplied should be dry, clean air (air drier: dew point approx. -20°C, air fil

-

ter: mesh size of approx. 0.01μm).

CAUTION

 

Turn off the power and air and make sure that the supply of air has been fully

shut off before carrying out any wire and tube connection work. If this is not

done, accidents or problems with operation may occur.

 

The metal parts of the nozzle are connected inside the product to the 0V and

GND terminal. Do not connect it to objects with a different electrical potential

such as the conductive parts of external devices. If the supplied air contains any

particles other than air or any corrosive gases, accidents or problems with opera-

tion may occur. In addition, if air which contains impurities such as carbon dust

or air which contains moisture or oil is used, accidents or problems with opera-

tion may also occur.

Do not modify the nozzle or install the nozzle to any other appliances, otherwise

correct charge removal performance may not be obtained, and accidents or

problems with operation may occur.

5

OPERATION

1.

 Use the mode select switches to select the required settings.

2. 

 Face the ionizer toward the electrostatically-charged object and pull the trigger.

When the trigger is pulled, dust removal operation will start, and when the trigger

is released, dust removal operation will stop.

Name

Position

Details

Pulse 

width

Cycle

Mode select switches

Pulse air mode 

selection

12

CONT

Pulse 1 (*)

12

CONT

Pulse 2 (*)

12

CONT

Continuous

LED illumination 

mode selection

ON SYNC OFF

Always ON

ON SYNC OFF

Synchronized with 

trigger

ON SYNC OFF

Always OFF

*:  Pulse 1: Pulse ionized air emission cycle approx. 100ms, pulse width approx. 50ms

  Pulse 2: Pulse ionized air emission cycle approx. 100ms, pulse width approx. 10ms

Ramco National

www.PanasonicSensors.com

1-800-280-6933

Reviews: