background image

6

CARE AND MAINTENANCE

 

 Be sure to turn off the power and air before carrying out cleaning and maintenance.

 

Make sure that the supply of air has been fully shut off and that all pressures at 

the product and inside the tubes are at zero before continuing. If this is not done, 

air pressure may cause operating problems or accidents.

 

 The discharge needle has a sharp point, so be very careful when cleaning the needle.

 

 Clean the discharge needle regularly about once a week, otherwise optimum charge re-

moval performance may not be obtained and accidents or operating problems may occur.

 

 The discharge needle is a consumable part. If charge removal performance does not return 

to normal after the discharge needle has been cleaned, then the needle should be replaced.

Cleaning and replacing the discharge needle

1. 

 Turn off the power and check that the air pressure inside the air tube has dropped to zero.

2. 

 Remove the nozzle guard, turn the nozzle counterclockwise and remove it.

3. 

 Remove the insulating pipe and the attachment. 

4. 

 When carrying out cleaning, use a cotton swab moistened in alcohol or similar to remove any 

dirt from the needle and the area around it. (If replacing the discharge needle, use needle nose 

pliers or a similar tool to pull out the needle, and then insert a new needle as far as it will go.)

5. 

 After cleaning or replacing the needle, return the attachment, insulating pipe and 

nozzle to their normal installation positions. Turn the nozzle clockwise to install it.

The tightening torque for the nozzle at this time should be 3N•m or less.

Lastly, affix the nozzle guard.

*:  Do not touch the tip of the discharge needle against tools or any other hard surfaces. If 

the discharge needle is damaged, optimum charge removal performance may not be 

obtained and accidents or problems with operation may occur. In addition, do not touch 

the stopper ring area, otherwise the stopper ring may slip out of position, and it may 

not be possible to reinstall it. When handling the discharge needle with tools, hold the 

discharge needle at the middle and avoid applying excessive force to the needle.

Note:  When installing the attachment, make sure that it is facing the correct direction. If it is installed so that it is facing 

the wrong direction, it will not be possible to fully tighten the nozzle.

Insulating pipe

Stopper ring

Discharge needle (*)

Attachment (Note)

Nozzle

Nozzle guard

*: Option (sold separately)

EC-GANT

 : Discharge needle 1 pc.

 

The solenoid valve is a consumable part (open/close operations: ap-

prox. 8,000,000). If it no longer opens and closes normally, stop using 

the ionizer and replace the solenoid valve.

Solenoid valve replacement procedure

1. 

 Check that the power is turned off and that the air pressure inside the air tube has 

dropped to zero.

2. 

 Remove the back cover. Remove the four M3 mounting screws. (A in diagram below)

3. 

 Disconnect the air tube from the solenoid valve. (B in diagram below)

4. 

 Disconnect the solenoid valve lead wire connector.

5. 

 Remove the two M3 mounting screws. (C in diagram below)

6. 

 Disconnect the air pipe from the solenoid valve. (D in diagram below)

7. 

 Install the new solenoid valve, and then install the M3×45 mounting screws and 

connect the air tubes and the solenoid valve lead wire connector. Tighten the 

M3×45 mounting screws at a torque of 0.2N•m or less.

8. 

 Install the back cover. Let the lead wire pass the lead wire holder, and make sure that the cov-

er will not catch lead wire. Tighten the M3×10 mounting screws at a torque of 0.4N•m or less.

*: Option (sold separately)

EC-GAV

: Solenoid valve 1 pc.

D: Air pipe

Solenoid valve (*)

B: ø8mm air tube

Lead wire holder

C: M3×4.5 mounting screw

A: M3×10 mounting screw

Fixed metal hook

Back cover

A: M3×10 mounting screw

(Tapping screw)

A: M3×10 mounting screw

(Tapping screw)

7

TROUBLESHOOTING

When an error is detected, the white LED flashes. (It also flashes even when the 

LED illumination mode is set to “Always OFF”.) If the white LED is flashing, carry out 

the following checking operations. When checking the discharge area, always be 

sure to turn off the power before carrying out the checking.

 

Turn off the power and check that the tip of the needle is intact and that there is 

no dirt on it, and that the needle is installed correctly.

 

Check that there are no foreign objects inside the nozzle.

 

 Check that the nozzle is installed correctly. (Including the attachment and the insulating pipe)

 

● Check that the air pressure is within the specification range.

8

SPECIFICATIONS

Type

Pulse Air-gun Ionizer

Model No.

EC-G02

Charge removal time

(±1,000V → ±100V)

0.5 sec. or less (Note 1)

Ion balance

±10V or less (Note 1)

Power supply voltage

Accessory AC adapter INPUT: 100 to 240V AC±10% 50/60Hz  (OUTPUT: 24V DC)

Power consumption

30VA or less

Discharge method

High-frequency AC method

Discharge output voltage

2000V approx.

Ozone generation

0.02ppm or less (Note 2)

Applicable fluid

Air (dried clean air)

External input

Ionized air emission operation ON/OFF using OR control with trigger switch

• 

Ionized air emission operation ON: Short-circuited to COM (-)

• 

Ionized air emission operation OFF: Open

Indicators

Valve illumination: Illuminated when solenoid valve is ON (open) (orange LED)

Error detection function

When an abnormal discharge (short-circuited, etc.) occurs, discharge is forcibly stopped 

and the spotlight flashes (reset when the power is turned off and back on) (N

ote 3)

Ambient temperature

0 to + 50°C (No dew condensation), AC adapter: 0 to +40°C

Ambient humidity

35% to 65% RH (No dew condensation)

Supplied air flow

Max. 300 ℓ/min. (ANR) or less

Air pressure range

0.05 to 0.50 MPa

Material

Enclosure: ABS, Nozzle: Stainless steel, Discharge needle: Tungsten

Nozzle guard: NBR

Weight

270g approx. (main unit only)

Accessories

• 

AC adapter 1 pc.

• 

 Exdusive intermediate cable (oil-proof / heat-proof / winding-proof type) length 2m: 1 pc.

• 

Straight joints

Tube outer diameter ø8mm-ø8mm compatible type 1 pc. (Note 4)

Tube outer diameter ø8mm-ø6mm compatible type 1 pc.

• 

Connector connection terminal (manufactured by Molex) 3 pcs.

Notes: 1) Typical value for continuous pulse air mode at 100mm from end of discharge nozzle at an applied air pres-

sure of 0.50MPa

 

2) Typical value for continuous pulse air mode at 300mm from end of discharge nozzle at an applied air pres-

sure of 0.25MPa

 

3) Once an error is detected, the error status is maintained until the power is turned off and back on again.

 

  Remove the cause of the error and then turn the power back on.

 

  If the cause of the error is not removed, the error will occur once more.

 

4) At the time of shipment from the factory, ø8mm-ø8mm type is attached.

9

CAUTIONS

 

This product has been developed / produced for industrial use only.

 

 Do not use this product for any purpose other than charge removal and dust removal.

 

● Do not use this product in enviroments which are outside the specification range, 

otherwise operating problems or damage may occur. In addition, the operating life 

of the product may become significantly reduced.

 

Never disassemble, repair or modify this product, otherwise operating problems or 

accidents may occur.

 

Do not dispose of this product by burning it, otherwise it may explode or toxic 

fumes may be generated.

 

This product generates ozone, so be sure to provide adequate ventilation if using 

it in a confined space.

 

Do not run the wires together with high-voltage lines or power lines or put them in 

the same raceway. This can cause malfunction due to induction.

 

Be sure to turn off the air and the power supply before carrying out any cable con-

nection or inspection work. If this is not done, operating problems, damage or 

electric shocks may occur.

 

After connecting the cables, check that the air piping and power supply connec-

tions are correct before turning on the power. If the wires or cables are connected 

incorrectly, operating problems or accidents may occur.

 

Verify that the supply voltage variation is within the rating.

 

Do not turn the power back on immediately after it has been turned off, otherwise 

operating problems or accidents may occur. In addition, the operating life of the 

product may become significantly reduced. Wait at least 2 seconds before turning 

the power back on again.

 

●  Do not use the power plug of the AC adapter if it has become dusty, otherwise fire 

may occur.

 

The air tube or cable may be broken if excessive tension or other stress is applied 

to the air tube and cable. Consider appropriate margins of the air tube and cable 

within the work area when using them.

 

Do not use any cables which have any damage (such as splitting or cracking), 

otherwise operating problems or accidents may occur.

 

Avoid using the product in places where there are high levels of steam or dust in 

the air or where it might be directly exposed to water, oil or welding spatter.

 

Do not touch the discharge needle with hard objects such as tools. If the dis-

charge needle becomes broken, it will not provide sufficient charge removal per

-

formance, and moreover operating problems or accidents may occur.

 

If this product ceases functioning or is no longer required, dispose of it according 

to appropriate local waste disposal regulations.

 

This product is a high-precision device, and should be handled with care.

10

INTENDED PRODUCTS FOR CE MARKING

 

 The models listed under “

8

SPECIFICATIONS

” come with CE Marking.

As for all other models, please contact our office.

 

Contact for CE

Panasonic Marketing Europe GmbH Panasonic Testing Center

Winsbergring 15, 22525 Hamburg,Germany

http://panasonic.net/id/pidsx/global

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

About our sale network, please visit our website.

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2014 

Ramco National

www.PanasonicSensors.com

1-800-280-6933

Reviews: