4

 

Measured ventilation rate is within 100-120% of HVAC contractor design value

4

 Rater shall measure ventilation and exhaust air flow using a flow hood, flow grid, 

anemometer or substantially equivalent method in accordance with AABC, NEBB  
or ASHRAE procedures

4

 

Intermittent bath fan measured air flow requirement ≥50 CFM

4

  Continuous supply and exhaust fans rated at 1.0 sones or less

4

 Exhaust-only whole-house mechanical ventilation system must be verified that  

the fan turns on automatically, without homeowner intervention

4

 All ventilation fans must be verified as ENERGY STAR certified

ENERGY STAR 3.0 

HVAC System  

Quality Installation  

Rater Checklist:

Static Pressure 

Graph  

Veri-Boost

 Integral Switch

 

Raters are now verifying the airflow of installed ventilation fans prior to certifying that they meet 
ASHRAE 62.2, ENERGY STAR 3.0 for Homes, LEED for Homes, CA Title 24, CalGreen and most 
Green Building programs. With so many fans on the market failing to deliver designed airflow, 
you need to spare yourself the hassle of having to rip out an under-performing fan and replace it. 
EcoVent’s built-in Veri-Boost

 switch provides a 20 CFM boost, which helps ensure the fan meets 

designed airflow requirements and provides Ventilation Verification Assurance: ≥50 CFM Installed 
Performance. Need to bump up the CFM output to meet code? Just flip the Veri-Boost

 Switch  

and you’re good to go. 

One of the most robust solutions for delivering Ventilation Verification Assurance.

EcoVent

 with Veri-Boost

 is the perfect solution for home builders looking for a cost effective, ENERGY STAR

®

 rated fan that not only 

delivers strong performance, but peace of mind during verification testing. So choose the powerful, eco-friendly solution that delivers the 
installed performance you need, from a company who sets the standard for quality and value.

Small Grille Design

The EcoVent grille is a smaller footprint (roughly 46% smaller) than comparable ESTAR fans. This design complements the aesthetics of your 
room by minimizing visual clutter on the ceiling. This makes EcoVent

 an ideal solution for the bathroom, powder room or laundry room area. 

Built-in Veri-Boost

 Switch

Balometer used to verify installed performance

EcoVent 

Ventilation Fan

PANASONIC HIGH PERFORMANCE SOLUTIONS PROVIDE 

VENTILATION VERIFICATION ASSURANCE

It is all about Measured Performance

Compliance with ASHRAE 62.2, the national ventilation standard, is now required for  
ENERGY STAR

®

 for Homes 3.0

Universal Can (U-Can) Contractor Packs

EcoVent

 is offered in contractor packs, whereby the housing and motor/grille 

assembly are packaged separately. This easy to manage package design allows 
contractors to store the components separately without the fear of parts getting 
lost or damaged on site. 

IT’S ALL ABOUT MEASURED PERFORMANCE.

EcoVent U-Can Contractor Packs

Model #

Description

Contents 

Master 

Pack*

FV-07VBA1 

Universal Housing Can

Housing Can, Duct Adaptor & Junction Box 

4

FV-07VBB1

Motor/Grille Assembly 

Motor & Grille

4

4" Duct, 70 CFM with Veri-Boost

(Fits in 2" x 6" construction)

*Must order in quantities of 4, shipment will contain 1 box with 4 pieces of each item. 

Static Pr

essur

e (Resistance)

Air Flow (CFM)

Closed or Blocked Duct Work

 – A closed or blocked exhaust port results  

in highest static pressure and zero air flow

Extended Duct Work

 – Long duct length and elbows 

increase static pressure and reduce air flow

Duct Work

 – Duct increases static pressure and 

reduces air flow

Short Duct Work

 – Short duct allows low 

static pressure and higher air flow

No Duct Work

 – No duct 

equals zero static pressure 

and maximum air flow