48
Problem
Cause and Remedy
The unit will not operate at all.
Upper body (neck to lower back) massage
Lower body (calves to seat) massage
Arm massage
•
•
•
The power cord has been disconnected. (See page 16)
The power switch on the unit has not been turned on.
A Pre-Program button or Manual Operation button hasn’t
been pressed after pressing
.
•
•
•
Sometimes the power won’t turn on when
is pressed
again when a massage has finished.
Approximately 5 seconds are required for program termination
after a massage finishes. Wait at least 5 seconds once all
movement has stopped before pressing
.
The unit has been damaged.
Stop using the unit immediately.
The power cord or power plug is abnormally hot.
Stop using the unit immediately.
Warning
Do not attempt to repair, disassemble or modify the unit.
Failure to observe this precaution may result in fire or injury due to malfunctioning.
•
Caution
Unplug the power plug immediately and contact a customer service center to arrange for repairs if the unit ceases to
function or is otherwise not working properly.
Failure to observe this precaution may result in electric shock or fire.
•
SPECIFICATIONS
Power supply
AC 120 V 60 Hz
Power consumption
195 W
Upper body massage
Massage area (Up-Down)
Approx. 30 in. (76 cm) (The massage heads move a total of approx. 26 in. (65 cm))
Massage area (Left-Right)
Distance between massage heads during operation (massage width adjustable)
Neck, Shoulder, Back, Lower back: Approx. 3 – 8 in. (7 – 21 cm)
Massage area (Forward-back) Projected amount of massage head (Intensity adjustable)
Approx. 4 in. (10 cm)
Massage speed
Tap: Approx. 250 – 450 cycles/minute (single side)
Full roll: Approx. 26 – 92 seconds (both ways)
Other than the above: approx. 6 – 50 cycles/minute
Lateral/Vertical Travel
Lateral travel: Approx. 1.5 in. (3.8 cm) left-right auto return
Vertical travel (Long): Approx. 30 in. (76 cm) up-down auto return
Vertical travel (Short): Approx. 4 in. (10 cm) up-down auto return
Massage width
Full roll, Vertical Movement: Approx. 3 – 7 in. (7 – 18 cm)
Other than the above: Same as massage area (left-right)
Air massage
Air Pressure (Calf)
5: Approx. 32 kPa
4: Approx. 30 kPa
3: Approx. 25 kPa
2: Approx. 19 kPa
1: Approx. 8 kPa
* It may vary with the area slightly.
Reclining angle
Backrest: Approx 120˚ – 170˚
Legrest: Approx 0˚ – 85˚
Automatic Shut-off
Automatically turns off after approx. 15 minutes (approx. 5 minutes for the quick massage)
Dimensions
When not reclined
(H × W × D)
Approx. 47.2 × 33.1 × 50 in. (120 × 84 × 127 cm)
When reclined
(H × W × D)
Approx. 28.3 × 33.1 × 76.8 in. (72 × 84 × 195 cm)
Weight of Unit
Approx. 181 lbs. (82 k
g)
Dimension of box (H × W × D)
Approx. 28.3 × 30.7 × 65.4 in. (72 × 78 × 166 cm)
Weight in box
Approx. 216 lbs. (98 k
g
)
Maximum user weight
Approx. 264 lbs (120 k
g
)
Minimum distance from wall
15.7 in. (40 cm)