8 -
ENGLISH
J
Replacement procedure
1) Turn off the power and then remove the AC power plug from the wall outlet.
z
Wait at least one hour and make sure the lamp unit and surroundings are cool.
2) Use a Phillips screwdriver to loosen the lamp cover fixing screw (one screw)
until it turns freely and remove the lamp cover.
z
Remove the lamp cover by pulling it slowly toward the direction of the arrow.
3) Use a Phillips screwdriver to loosen the lamp unit fixing screws (three screws)
until they turn freely.
4) Hold the used lamp unit by its handles, and pull it gently from the projector.
5) Insert the new lamp unit in correct direction. Tighten the lamp unit fixing
screws (three screws) securely with a Phillips screwdriver.
z
When you experience difficulty in installing the lamp unit, remove it and try again. If you use
force to install the lamp unit, the connector may be damaged.
6) Attach the lamp cover. Tighten the lamp cover fixing screw (one screw) se-
curely with a Phillips screwdriver.
z
Perform step 2) in reverse direction to attach the lamp cover.
Handles
Replacing the Lamp unit ( continued )
Lamp cover fixing screw
Lamp cover
Lamp unit fixing screws