ENGLISH - 17
Hex head bolt,
captive washer
Pole base
Hook
2)
Fit the finger tightened captive washer hex head
bolts in the pole base (the attachment plate for a
ceiling mount bracket for low ceilings) in the hooks
on the angle adjusting bracket.
Attention
z
Make sure that the finger tightened captive washer
hex head bolts are firmly engaged with the thread
ridges of the pole base (the attachment plate if a
ceiling mount bracket for low ceilings is used).
z
Hold the projector firmly until the captive washer
hex head bolts are securely placed in the hooks on
the angle adjusting bracket.
WARNING:
Mounting and installation must be carried out
by two or more persons.
Hex head bolt,
captive washer
Hex head bolt,
captive washer
3) Use the two captive washer hex head bolts
removed in the section "Removing the projector
from the existing bracket" to secure the pole base
(the attachment plate for a ceiling bracket for low
ceilings) and the angle adjusting bracket as shown
in the figure on the left.
Attention
z
After mounting the projector on the ceiling mount bracket, adjust the installation angle.
For information on how to adjust the installation angle, refer to the installation instructions or other instructions
supplied with the ceiling mount bracket (for low or high ceilings).
Using an existing bracket (continued)
ET-PKD130B_EN_TQZJ577-7.indd 17
2017/03/13 19:05:06