background image

4

The slit mask is only available for the thru-beam type sensor.

Optional slit masks help the sensor detect small objects. The accuracy of
the position being sensed is also increased. However, the sensing range is
reduced.

Mounting method

The tightening torque should be 0.5N·m or less.

1

Slip the slit mask onto the sensor.

2

Align the holes and mount with the M3
screws provided.

The optional mounting spacer is only available for front sensing type
sensors.

Part no.

: MS-EX20-FS.

Mounting method

The tightening torque should be 0.5N·m or less.

1

Fit the mounting spacer on the sensor.

2

Align the holes and mount with the M3 screws
provided.

The following symbols are used in this section.

 NPN output type

Only the thru-beam receiver incorporates the output.

PNP output type

Only the thru-beam receiver incorporates the output.

7

SLIT MASKS

Sensor type

Slit mask 

model no.

Description

EX-21

OS-EX20-05

Slit diameter: 0.5mm.

OS-EX20-05X3

Slit: 0.5 x 3.0mm.

EX-23

OS-EX20E-05

Slit diameter: 0.5mm.

OS-EX20E-05X3

Slit: 0.5 x 3.0mm

8

MOUNTING SPACER

M3 

M3

9

I/O CIRCUIT DIAGRAMS

Symbol

Meaning

D

Reverse supply polarity protection diode

Z

D

Surge absorption zener diode

Tr

1

NPN output transistor

Tr

2

PNP output transistor

+

-

±10%

D

Z

D

T

r1

Color code

Sensor circuit

12 to 24V DC 

Load

Users' circuit

Internal circuit

(Brown) +V

(Black) Output (note)

(Blue) 0V

50mA max.

D

+

-

±10%

Z

D

T

r2

Sensor circuit

Color code

(Brown) +V

Load

50mA max.

(Black) Output (Note)

(Blue) 0V

Users' circuit

Internal circuit

12 to 24V DC 

Rugghölzli 2

CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

mailbox@sentronic.com

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Reviews: