4
The slit mask is only available for the thru-beam type sensor.
Optional slit masks help the sensor detect small objects. The accuracy of
the position being sensed is also increased. However, the sensing range is
reduced.
Mounting method
The tightening torque should be 0.5N·m or less.
1
Slip the slit mask onto the sensor.
2
Align the holes and mount with the M3
screws provided.
The optional mounting spacer is only available for front sensing type
sensors.
Part no.
: MS-EX20-FS.
Mounting method
The tightening torque should be 0.5N·m or less.
1
Fit the mounting spacer on the sensor.
2
Align the holes and mount with the M3 screws
provided.
The following symbols are used in this section.
NPN output type
Only the thru-beam receiver incorporates the output.
PNP output type
Only the thru-beam receiver incorporates the output.
7
SLIT MASKS
Sensor type
Slit mask
model no.
Description
EX-21
OS-EX20-05
Slit diameter: 0.5mm.
OS-EX20-05X3
Slit: 0.5 x 3.0mm.
EX-23
OS-EX20E-05
Slit diameter: 0.5mm.
OS-EX20E-05X3
Slit: 0.5 x 3.0mm
8
MOUNTING SPACER
M3
M3
9
I/O CIRCUIT DIAGRAMS
Symbol
Meaning
D
Reverse supply polarity protection diode
Z
D
Surge absorption zener diode
Tr
1
NPN output transistor
Tr
2
PNP output transistor
+
-
±10%
D
Z
D
T
r1
Color code
Sensor circuit
12 to 24V DC
Load
Users' circuit
Internal circuit
(Brown) +V
(Black) Output (note)
(Blue) 0V
50mA max.
D
+
-
±10%
Z
D
T
r2
Sensor circuit
Color code
(Brown) +V
Load
50mA max.
(Black) Output (Note)
(Blue) 0V
Users' circuit
Internal circuit
12 to 24V DC
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG