background image

6

*3

The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. The sensing range specified refers to the 

setting range for the sensor when used with the reflector; the sensor itself can detect an object less than 30mm away. If the distance to the reflector is 100mm 
or less, the sensing object should be opaque.

*4

With 200 x 200mm non-glossy paper. If you use this product at a sensing range of 50mm or less, the sensitivity adjustment range becomes extremely narrow.

*5

Convergence point: 10mm. With 50 x 50mm white non-glossy paper.

*6

Convergence point: 10mm. With 50 x 50mm white non-glossy paper. Spot diameter 1mm with a setting distance of 10mm.

*7

With 100 x 100mm white non glossy paper. Spot diameter 5mm with a setting distance of 80mm.

*8

Setting distance between emitter and receiver: 1m.

*9

Setting distance between emitter and receiver: 2m.

*10

Setting distance: 10mm.

*11

Min. ø1mm copper wire. Setting distance: 80mm.

Rugghölzli 2

CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

mailbox@sentronic.com

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Reviews: