background image

Timer button

(P.16)

Humidity

button
(P.11)

Clean,deodorization

button 

(P.14)

Auto

button
(P.13)

Function

selection

button
(P.10)

Air volume

button (P.12)

Display screen

Auto indicator 

(P.13)

Auto indicator 

(P.10)

ECONAVI

indicator (P.10)

(P.10~p.13)

(P.16)

Front display (P.12)

(P.16)

(P.15)

(P.17)

(P.10)

(P.10)

Unpowered

Powered on

Full

(water display flash)

Factory setting

HEPA filter cleaning 
and reset
HEPA filter replacement 
and reset

            +            

            +            

LED light brightness 
setting

            +            

            +            

Filter life query

Security lock setting

Activated carbon filter 
replacement and reset

Sound setting

Security lock setting

Press the

button for about 3 seconds.

Press the

buttons for about 3 seconds.

Press the

button for about 3 seconds.

Press the

button for about 3 seconds.

Press the

button for about 3 seconds.

Press the

button for about 3 seconds.

Press the

button for about 3 seconds.

Press the

button for about 3 seconds.

Press the

buttons for about 7 seconds.

How to use combination key

In standby

Running

7

YAV28H

Summary of Contents for F-YAV28H

Page 1: ...F YAV28H Brightness Ϯ ŝŶ ϭ ŝƌ WƵƌŝĨLJŝŶŐ ĞŚƵŵŝĚŝĮĞƌ ...

Page 2: ...2 ...

Page 3: ...3 YAV28H ...

Page 4: ...4 ...

Page 5: ... the HEPA filter Write down the beginning date of service on the sticker and attach it to the unit Before using please remove the cushioning pad under the louvers otherwose the airflow will be reduced resulting in decreased Cushioning pad Louver 5 YAV28H ...

Page 6: ...ters with brakes 2 at the bottom rear of the main body Please peel off the protective Front Display P 20 Brake wheel P 18 P 20 The water tank may contain water residue at time of purchase This is from final product testing at the factory and is not due to a defect 6 ...

Page 7: ...HEPA filter replacement and reset LED light brightness setting Filter life query Security lock setting Activated carbon filter replacement and reset Sound setting Security lock setting Press the button for about 3 seconds Press the buttons for about 3 seconds Press the button for about 3 seconds Press the button for about 3 seconds Press the button for about 3 seconds Press the button for about 3 ...

Page 8: ...8 ...

Page 9: ...on the body the value detected by the PM2 5 sensor may be inaccurate The color of PM1 0 changes according to the color currently displayed by the PM2 5 sensor The concentration detected by the PM2 5 sensor may be different from the data detected by other devices Front Display 9 PM2 5 PM1 0 YAV28H ...

Page 10: ...the indoor temperature The unit adopts HEPA and deodorant filters to provide the effects of bacterial resistance dust removal and deodorization When the filter is detected by the filter detector the will light up as you press down the Function selection If no filter is installed the will not light up when the Function selection button is pressed The will light up when only the air purifying functi...

Page 11: ...P 12 P 15 17 16 16 11 YAV28H ...

Page 12: ... only be selected in the Operation mode and Humidity setting modes Select the operation mode according to P 10 P 11 before setting Press to select Press to select Factory default The airflow can adjust when in Fan mode Only Airflow in Auto mode the air flow will be changed by the volume of PM2 5 and maloder Yoru product may enter protection mode with air volume and direction in case room temperatu...

Page 13: ...inder ON OFF can be set In the Auto mode press the Power Off On button to end the Auto mode or switch to other functions Humidity setting Press to select Skip this step End Auto Press the button in the standby mode the Auto indicator flashes The humidity setting lights up press the button to set the humidity If the humidity is set wait for about 3 seconds and automatically enter the Auto mode If n...

Page 14: ...14 Purifying ...

Page 15: ... 2 2 Down Up Auto Auto Below Up Auto 15 2 Carpetăfloor and shoes etc According to the actual needs adjust the machine to an appropriate position so that the air can blow to the place that needs to be dehumidified YAV28H ...

Page 16: ...during the flashing to select the setting Exit sound settings The setting will be exited if there is no operation after the text in the LCD sound area flashes for about 5 seconds or another function button is pressed Brightness setting factory default is full brightness When the humidity button is pressed for about 3 seconds when running the LED light of the operation panel can be adjusted but the...

Page 17: ...17 Hold down the machine body with your thumb and then take out the water tank water display flash and front display panel shows water full YAV28H ...

Page 18: ...18 ...

Page 19: ... 19 Folding on both sides Turn the tank handle up and fold both sides of the tank cover When installing the folding on both sides of the water tank cover it may sink if the force is too great 7 YAV28H ...

Page 20: ...ter press the button for about 3 seconds according to the instructions on the front display and the warning screen on the front display will be cleared When the filter cleaning or replacement is not exited the filter cleaning or replacement reminder will be displayed for 10 seconds each time the machine is turned on If the HEPA filter has reached its service life after another 500 hours of running...

Page 21: ...F YAV28H 3 5 5 3 5 3 7 5 Friendly reminder You can remove HEPA filter when in Laundry mode using ECONAVI so as to shorten laundry time Please reinstall the HEPA filter after laundry 21 YAV28H ...

Page 22: ...22 Safety protection P 8 7 6 7 P 19 7 20 Is there a magnet or metal placed above the machine body Error action Is there any foreign matter water or dust on the control panel P 8 ...

Page 23: ... purple even if the unit operates continuously The air is dirty but the PM2 5 PM1 0 detection indicator still lights in green Is the PM2 5 PM1 0 sensor dirty P 20 Is the PM2 5 PM1 0 sensor dirty P 20 When the operation mode and air volume change the PM2 5 PM1 0 sensor may take a longer time to detect YAV28H ...

Page 24: ...abnormally heats up and there is a scorching smell Other abnormalities or malfunctions When you have these problems please turn off the power to prevent accidents When the dehumidifier stops running the power consumption is about 1 W Unplug the power plug when the power plug is inserted and contact the service center or dealer For electrical appliances that have been used for many years please tak...

Page 25: ...YAV28H 25 ...

Page 26: ...C8041 3920 2022 10 2022 10 F YAV28H 1 25 26 ...

Reviews: