Operation manual for Narrow-pitch connectors F4S
Panasonic Corporation
industrial.panasonic.com/ac/e/
©
Panasonic Corporation 2017
ACCTF5E-5 201704
- 15 -
03. Precautions for mounting and reflow soldering
03-1. Points to consider when selecting a pickup nozzle
for mounting
Select a pickup nozzle with a suction area that demonstrates a theoretical lifting force
at least
10 times
greater than the connector weight. .
Theoretical lifting force (g)
= Vacuum pressure (mmHG) /760
×
1.033
×
Nozzle area (cm
2
)
Example of machine vacuum pressure setting: 480–520 mmHg
■
Picking up the socket
(1)The suction area on the socket is 0.8 mm in
the shorter direction.
●
Example of the nozzle (Source: Panasonic Factory)
Number of contacts
A
B
C
D
10
1.4
1
1
0.5
20-30
3.9
1
2.4
0.5
40-50
8
1
6
0.5
●
Single connector weight (socket)
10 contacts
20 contacts
30 contacts
40 contacts
50 contacts
Socket
0.018
0.026
0.034
0.042
0.051
Socket
(Unit
;
g)
(Unit:mm)