background image

12

11

Mounting a terminal plug

Connection of the electrical wires

Remove the set screws to remove the cover.
Loosen the cable clamp securing screws and insert the 
electrical cableinto the cover.
Connect the electrical wires to the terminal board by either 
using crimp terminals or by winding the wires around the 
terminals.
Fit the cover into the body and secure it by tightening the set 
screws.
Tighten the cable clamp securing screws to secure the 
electrical cable.

Mounting reeler outlet

Dismounting plug

Pull up the plug lever, and then rotate it counterclockwise by 

   

90 degrees.

Up-and-down handling the outlet

Retaining the cap of fixture used

Hitch the cord on the cord hook of the outlet to use the fixture.

To mount the reeler outlet, pull down the plug lever, andthen 

   rotate it clockwise by 90 degrees.

Procedure for mounting and

using reeler outlet plug

Securely fasten the terminal screws.

 (Proper torque: 0.8 N・m 〜 1 N・m)

  

Doing so may result in a fire.

Do not slide the plug with having come in the duct.

  

Doing so may result in faulty connection, thus leading to a fire.

Caution

Notes

Do not attach the plug unit where the tapping screw is used 

the duct directiy

Notes

Do not attach the plug unit where the tapping 

screw is used the duct directiy

1.
2.

3.

4.

5.

Do not slide the plug with having come in the duct.

  

Doing so may result in faulty connection, thus leading to a fire.

Caution

The outlet can expand and contract in the range of 
approximately 80 to 180 cm from the mounting surface.
Pull down the main body of the outlet. It stops in a position in 
which pull down.
To return the main body to the original position, press and 
hold the pushbutton press and hold the pushbutton to push up 
the main body to a position to which you want to return it. 
(Releasing the pushbutton will stop it on the spot.)

Duct

Lever

Polarity indication
(ground side) 

Terminal Plug

Ground terminal

M3.5

 

Cover

Securing screw

Set screw 

Body

Terminal screw

M3.5

Terminal board

Cable clamp

Duct

Lever

Polarity indication
(ground side) 

Reeler 

outlet plug

reeler outlet

Cord hook

Push button

9

Summary of Contents for Factory Line 20

Page 1: ...your electrical worker to take necessary actions In such case be sure to pass Instruction and Installation Manuals Not doing so will result in an electric shock a fire or a drop Use the rated voltage within the load capacity that is always displayed Not doing so will result in a fire Use Fluorescent lighting plug below a permissible load Not doing so will result in a fire or a drop Caution this pr...

Page 2: ...he smoke rises The place which is subject to the influence of heat such as the upper part of a heater Not doing so will result in an electric shock a fire or a drop Do not install the Factory Line duct passing through building structure Doing so may result in a fire Do not slide putting the plug in the duct Poor contact will cause a fire During construction Do not give a shock such as dropping on ...

Page 3: ...ceiling side directly Are there loose the screw Retighten Are there discoloration or deformation in the plastic of the duct and Change it Are there adhesion and deposition of dust in the inside of a duct Remove the dirt Is a straight line connecting duct Attachment is improved so that it may become a straight line Is the thing which is not an exclusive plug attached to the duct Exchange plugs The ...

Page 4: ... mm mount the flange and then mount a pipe to the flange Unit mm Mounting the ducts directly to the ceiling Support spacing for the duct 1 Turn the flange cover to the left to remove it 2 Use the wood screw or tapping screw then mount the flange to a structural member 3 Align the pipe mounting hole of the pipe suspension hanger with the position of the pan head machine screw to put the pipe in the...

Page 5: ...via the pipe suspended hangers method for bringing in the power supply Route the cable from the ceiling into the pipe When doing this it is easier if the cable is passed through the pipe before securing the Factory Line 20 duct in the hanger Following the same procedure for Step fit the duct in the hanger and then fix it with the cap Use single conductor cables of 1 6 or 2 0 m in size Make wire co...

Page 6: ... duct into the hanger and then turn the cap to the right and tighten the securing screw in order to secure the duct Ensure the strength of building structures enough to support the hanging weight a maximum of 10 kg per support Not doing so may cause the hanger to drop To use long hanger bolts mount these bolts using sway braces Use two or more pieces of hanger for one duct It will become a cause o...

Page 7: ...rew During construction Do not give a shock such as dropping on a product or hitting It may be damaged Combine the tip of a duct and connect certainly Connect a straightly both of the duct Securely fasten the set screws Proper torque 0 98 N m 1 32 N m Doing so may result in an electric shock or a fire When cutting the ducts use a metal hacksaw hand type and cut with the opening in the duct facing d...

Page 8: ...y cable of the grounded side to the Polarity indication ground side the terminal screw of which is plated Caution Set screw Polarity indication ground side Polarity indication ground side Duct Duct Grund terminal M4 Terminal screw plated To connect the duct with the center feed in joiner be sure to align the Polarity indication ground side with each other Only to make connection the cover needs no...

Page 9: ...ng so may result in a fire Do not slide the plug with having come in the duct Doing so may result in faulty connection thus leading to a fire Caution Notes Do not attach the plug unit where the tapping screw is used the duct directiy Notes Do not attach the plug unit where the tapping screw is used the duct directiy 1 2 3 4 5 Do not slide the plug with having come in the duct Doing so may result in ...

Page 10: ...g the lever duct outlet plug lever lock Notes Do not attach the plug unit where the tapping screw is used the duct directiy Do not slide the plug with having come in the duct Doing so may result in faulty connection thus leading to a fire Caution 13 Mounting an electrical outlet plug Mounting plug Matching the polarity indications on the duct and the plug insert the plug into the duct and rotate it...

Page 11: ...ut Fluorescent lighting plug Power supply hole Locknut Mounting fluorescent lighting fixture to the duct fluorescent lighting plug and clamp lever handling method To mount Rotate clockwise until the lever no longer rotates To dismount Rotate counterclockwise until the lever no longer rotates To connect the cable to unthreaded terminal use bar type crimp style terminal Not doing so may result in fault...

Page 12: ...oster might discolor and begins to burn because of the heat of the illuminator Caution Duct Opening Duct cover Use the poster clip to suspend a work instruction sheet or process chart from the Factory Line 20 Fold down about 10 mm of the top of the work instruction sheet or process chart and slide it sideways into the poster clip The work instruction sheet can be positioned in the desired directio...

Reviews: