background image

be vacuumed with a soft brush attachment.

Exchange Capillary Core 

Whisper Comfort's unique core is made from a paper-like mate-
rial and should never be washed or submerged in water. To clean, 
vacuum with a soft brush attachment.

INSTALLATION

Mounting 

WhisperComfort measures 14" wide and fits between joists 16" on 
center. Adjustable brackets and screws are provided to secure the 
unit to the joist on 4 corners.

Wiring 

Power consumption is 23 Watts at 40 CFM with a power rating of 
120/60 V/Hz. Bring house power to the unit junction box and use 3 
wires to connect the 2 switches.

Duct 

Insulated 4" duct is recommended. For cold climates, this will help 
avoid condensation build up. And for warm climates, this will help 
reduce heat transfer to supply air.

In order to reduce unnecessary airflow resistance, duct should be 
stretched straight and braced to avoid sagging. Assure that all duct 
connections are completely secured with duct tape and/or duct 
mastic material.

Elbows 

To achieve optimum performance, first, allow a 2 – 3 foot straight 
run out of the unit before the first elbow for air flow momentum. An 
installation that has a 90-degree elbow immediately after the fan 
exhaust port will cause air to back flow into the fan. 

Second, use a long radius angle to help ensure optimum airflow 
and minimum noise. 

Termination/Supply Device 

The supply device will need to have the back draft damper 
removed and replaced with a screen to prevent insects and 
small animals from nesting.

The termination and supply devices should be placed a 
minimum of 3-feet apart. If placed closer than 3-feet, then the 
angle of each device should be mounted at 45-degrees in 
opposite directions.

Optional Accessory – Exterior Wall Cap

Unlike previous installations where two wall caps were 
required, WhisperComfort’s FV-WC04VE1 polypropylene wall 
cap accessory with styrofoam adaptor conveniently allows 
both exhaust (from the right) and supply (from the left) airflow 
through a 5.5"-5.75" hole in the building envelope.  And 
due to the dividers inside the bottom portion of the unique 
Y-shape chamber and the new wall cap, cross contamination 
is prevented.

MAINTENANCE (Cleaning)

Maintenance instructions can be found in the Operating Manual.

Grille 

Follow the Operating Manual to remove 
the grille from the unit. Next, remove the 
filter from the inside louver of the grille. 
Never use gasoline, benzene, thinner or 
any other chemicals when cleaning the 
grille or ERV unit. Do not wash grille in a dishwasher which may 
cause it to deform. Instead, use light dish soap.

Filters 

WhisperComfort has two air filters. One filter is located on the 
inside louver of the grille. The second filter is located in the unit 
held by a bracket with a handle. Pull the handle to remove the filter 
bracket and remove the filter from the bracket. Both filters should 

Grille

Exchange  

Capillary Core

Supply Air Filter

Exhaust Air 

Filter

3' 

(920 mm)

Supply hood 

should include 

a bird screen 

with backdraft 

damper removed

Exhaust hood 
should include 
a backdraft 
damper

Alternative Wall Cap Installation

SUPPLY

Optional Exterior Wall Cap – 
Model # FV-WC04VE1

EXHAUST

Standard Wall Cap Installation

Reviews: