background image

Fig.12

10

CAUTION

CAUTION

WARNING

Fig.13

INSTALLATION (NEW CONSTRUCTION) CONTINUED

INSTALLATION (RETROFIT)

1. Remove the existing fan and cut ceiling openning.

2. Follow the step 1, 4, 5 on page 8 and step 7 on 
    page 9. (Before connect the circular duct to the 
    adaptor, should pull down the circular duct from 
    the ceiling)

Disconnect power source before working 
on unit.

5. Follow the step 10 to 16 on page 9 to 10.

TM

    Secure the Flex-Z Fast  bracket to joists by using 4 
    tapping screws (ST4.2x20) (Please prepare the 

TM

    screws and put on Flex-Z Fast  bracket before 

TM

    Flex-Z Fast  bracket is installed on joist). 
    Existing ductwork and wiring left in place. (Fig.14) 

TM

3. Install the adaptor to Flex-Z Fast  bracket by using
    2 self-drilling screws. (Fig.15)

Grille

Ceiling

Gloves

Mounting spring

16. Insert the other mounting spring into the slot 
      as shown and mount grille to fan body. (Fig.13)

Mount grille carefully so that lead wire of 
lighting unit is not pinched.

TM

4. Secure the fan body to Flex-Z Fast  bracket by 
    using 2 self-drilling screws, plug connector to 
    receptacle and secure the fan body to adaptor 
    by using machine screw (M4X6). (Fig.16)

Secure machine screw (M4X6) to the suitable 

TM

hole and not touch the Flex-Z Fast  bracket.
Please fix the screw carefully to avoid screw 
slip teeth.

Ceiling

Flange

Joist

Machine screw (M4X6)

2 Self-drilling screws (Fix the 

TM

flange and Flex-Z Fast  bracket through the ceiling)

15. Adjust Pick-A-Flow switch; if used, adjust the 
      FV-VS15VK1 Multi-Speed module. (Fig.12) 
      Refer to indication on page 6. 

14. Plug in the specified devices as your choice 
      (refer to installation on page 8). Insert the 
      motion sensor (FV-MSVK1 only) or LED night 
      light (FV-NLVK1 only) into slot of the grille. 
      Fix the lead wire into the clasp (Fig.11).

CAUTION

Before turn on the light, make sure the 
connector at the correct position. If not,
the lighting can’t work.

The claw of connector must latch the rib 
completely. 

Grille

Ceiling

Fig.11

Ceiling

Motion sensor
(FV-MSVK1 only)

Mounting spring

LED night light
(FV-NLVK1 only)

Gloves

Plug
connector

Inser plug
connector

Lighting 
unit

Clasp

Rib

Claw

Fig.15

Mastic or 
approved 
foil tape

2 Self-drilling screws

Ceiling

Joist

Knock-out 
hole

Junction box
cover

Conduit

Circular duct

Fig.14

10 7/8 

(275)

10 7/8 (275)

Ceiling (already existed)

Conduit Circular duct

Joist

   4 Tapping 
screws (ST4.2x20)

Fig.16

Unit: inches (mm)

Summary of Contents for FV-05-11VKSL1

Page 1: ...1 15VKL1 INSTALLATION INSTRUCTIONS Ventilating Fan Model No Contents FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models 2 3 3 4 4 4 5 5 5 6 6 7 7 8 8 10 10 11 11 BACK COVER BACK COVER BACK...

Page 2: ...ibe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed To reduce the risk of fire electric shock or injury to persons observe the fo...

Page 3: ...th a method which is not approved in the instructions WARNING This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmon...

Page 4: ...gral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A...

Page 5: ...ight Neutral Power supply AC120V 60Hz AC120V 60Hz Power supply Neutral Black Red Red Green Earth ground Green White White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module s...

Page 6: ...the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM...

Page 7: ...ecessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICAT...

Page 8: ...or from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from...

Page 9: ...black Light Netural to white Netural to white Junction box Two red wires Connect to a general manual wall switch Earth ground to green INSTALLATION NEW CONSTRUCTION CONTINUED CAUTION CAUTION Machine s...

Page 10: ...fan body to adaptor by using machine screw M4X6 Fig 16 Secure machine screw M4X6 to the suitable TM hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth...

Page 11: ...t immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C WARNING CAUTION 4 Install the LED lamps CX GU24 H B 7W as shown in step 1 and step 2 of Fig 9 Page 9 WARNING Rem...

Page 12: ...rection Exhaust Exhaust Exhaust 4 or 6 Exhaust Voltage V Voltage V Frequency Hz Frequency Hz Noise sones Noise sones Speed rpm Speed rpm Power W Power W Fan Fan Lighting unit Lighting unit Weight lb W...

Reviews: