background image

7

FV-CSVK1 Condensation Sensor module

 turns the base fan on or 

boosts to higher speed when humidity is detected when used in 
combination with the FV-VS15VK1. The Condensation Sensor works 
based on calculations from the Psychrometric Chart, or combination 
of Relative Humidity (RH) and Temperature. This allows the fan to 
anticipate the formation of condensation and automatically turn on 
when needed to expel humid air. The Condensation Sensor is pre-set 
to run for 20 minutes; it will then check the RH and Temperature to 
detect if the fan needs to run for another 20 minutes cycle.

FV-MSVK1 Motion Sensor module 

turns the base fan on or boosts 

to higher speed when motion is detected when using in combination 
with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 
minutes; it will then re-check for movement; if detected the fan will 
run for another 20 minutes cycle. The Motion Sensor detects within 
the range shown below.

TM

FV-NLVK1 Nite-Glo  LED Night Light module 

automatically turns on 

when ambient light levels are met. Turning the dial on the Modular 
Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room 
with little ambient light from nearby rooms. Turning the dial to 
‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is 
necessary to connect wall switch when only plug in FV-NLVK1, fan can 
operate on high speed with wall switch control, fan can also operate 
on low speed when used in combination with the FV-VS15VK1.)

INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED 

The distance that motion 
can be detected is limited
to 10 feet (3m). The field 
of view of the sensor is 90

°

.

(Room temperature is 25 C).

PLUG ‘N PLAY Modular Component Accessories

Sold Separately, Not Included With Base Model Fan

PLUG ‘N PLAY Modular Component Accessories

Sold Separately, Not Included With Base Model Fan

FV-CSVK1 + FV-MSVK1

FV-CSVK1 + FV-VS15VK1

Turns the fan on for 20 minutes when either 
motion or excess humidity is detected.

Cycles the fan to  high speed from low speed 
for the amount of time selected on the Control 
Dial based upon detection of excess humidity.

MOTION (PLUG ‘N PLAY FUNCTION DEVICES) 

PLUG ‘N PLAY Modular 
Components used in 
Combinations

FV-MSVK1 + FV-VS15VK1

Cycles the fan to  high speed from low speed 
for the amount of time selected on the Control 
Dial based upon motion within the room.

Fan 
operation

Time delay 
operation

OUTSIDE

Human 
active

Motion

Module FV-MSVK1, 

FV-CSVK1 (Not 

included)

INSIDE

FV-CSVK1 only

Fan 
ON/OFF

20 minutes 
time delay

FV-MSVK1 only

Fan 
active

At low 
speed

When motion or 
excess humidity is 
detected, fan runs 
at high speed.

Remains running 
at high speed until 
the delay time has 
passed.

FV-CSVK1 + FV-VS15VK1

Fan 
Hi/Low speed

Depend on 
FV-VS15VK1 Time 
delay setting

FV-MSVK1 + FV-VS15VK1

Summary of Contents for FV-05-11VKSL1

Page 1: ...1 15VKL1 INSTALLATION INSTRUCTIONS Ventilating Fan Model No Contents FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models 2 3 3 4 4 4 5 5 5 6 6 7 7 8 8 10 10 11 11 BACK COVER BACK COVER BACK...

Page 2: ...ibe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed To reduce the risk of fire electric shock or injury to persons observe the fo...

Page 3: ...th a method which is not approved in the instructions WARNING This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmon...

Page 4: ...gral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A...

Page 5: ...ight Neutral Power supply AC120V 60Hz AC120V 60Hz Power supply Neutral Black Red Red Green Earth ground Green White White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module s...

Page 6: ...the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM...

Page 7: ...ecessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICAT...

Page 8: ...or from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from...

Page 9: ...black Light Netural to white Netural to white Junction box Two red wires Connect to a general manual wall switch Earth ground to green INSTALLATION NEW CONSTRUCTION CONTINUED CAUTION CAUTION Machine s...