background image

9

8. Insert fan body and slide into adaptor assy with some 

TM

    strength, untill the flange overlaps the Flex-Z Fast  

TM

    bracket. Secure the fan body to Flex-Z Fast  bracket 
    by using 2 self-drilling screws, plug connector to 
    receptacle and secure the fan body to adaptor by 
    using machine screw (M4X6). (Fig.6)

Mount junction box cover carefully so that 
lead wires are not pinched.

Secure machine screw (M4X6) to 

TM

hole and not touch the Flex-Z Fast  bracket.
Please fix the screw carefully to avoid screw 
slip teeth.

the suitable 

7. Refer to wiring diagram on page 5.
    Follow all the local electrical safety codes as well
    as the National Electrical Code (NEC).
    Using UL approved wire nuts, connect house 
    power wires to ventilating fan wires. (Fig.5)

Fig.5

FV-05-11VKSL1
FV-05-11VKL1
FV-11-15VKL1

Fig.6

10. Remove the tapes from louver and springs before 
      installation. Remove screw (M4X8) and light cover. 
      (Fig.8)

Conduit

Wire nut

Live to black
(Fan)

Live to black
(Light)

Netural to white

Netural to
white

Junction 
box

Two red wires (Connect 
to a general manual 
wall switch)

Earth ground to green

INSTALLATION (NEW CONSTRUCTION) CONTINUED

CAUTION

CAUTION

Machine 
screw

 

(M4X6)

2 Self-drilling 
screws

Joist

Plug connector

Receptacle

9. Finish ceiling work. Ceiling hole should be aligned
    with the inside edge of the flange. (Fig.7) 

Fig.7

10 1/2 

(270)

10 1/2 

(270)

Ceiling

Unit: inches (mm)

After finishing the ceiling job, fill gap between flange
and ceillng with caulk or other sealant to prevent air
leakage

Fig.8

Fig.10

Secure 
screw
(M4X8)

Fig.9

LED  lamp

Remove screw
(M4X8)

Light cover

Light cover

Tapes

IMPORTANT:

Replace the sensor cover before the installation 
(only for plug-in Motion sensor module FV-MSVK1).  
As shown below:

11.  Install  the  LED  lamps.  (Fig.9)

12.  Install  light  cover.  (Fig.10)

13. Insert the grille mounting spring on the wiring side 
      into the slot and insert the plug connector into the 
      housing of the lighting unit. (Fig.11 of page 10)

Keep on pressing the clasps when removing the ornamental cover.

Ornamental 
cover

Sensor 
cover

Insert the sensor cover (attachment for FV-MSVK1) into slot.

Gloves

Summary of Contents for FV-05-11VKSL1

Page 1: ...1 15VKL1 INSTALLATION INSTRUCTIONS Ventilating Fan Model No Contents FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models 2 3 3 4 4 4 5 5 5 6 6 7 7 8 8 10 10 11 11 BACK COVER BACK COVER BACK...

Page 2: ...ibe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed To reduce the risk of fire electric shock or injury to persons observe the fo...

Page 3: ...th a method which is not approved in the instructions WARNING This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmon...

Page 4: ...gral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A...

Page 5: ...ight Neutral Power supply AC120V 60Hz AC120V 60Hz Power supply Neutral Black Red Red Green Earth ground Green White White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module s...

Page 6: ...the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM...

Page 7: ...ecessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICAT...

Page 8: ...or from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from...

Page 9: ...black Light Netural to white Netural to white Junction box Two red wires Connect to a general manual wall switch Earth ground to green INSTALLATION NEW CONSTRUCTION CONTINUED CAUTION CAUTION Machine s...

Page 10: ...fan body to adaptor by using machine screw M4X6 Fig 16 Secure machine screw M4X6 to the suitable TM hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth...

Page 11: ...t immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C WARNING CAUTION 4 Install the LED lamps CX GU24 H B 7W as shown in step 1 and step 2 of Fig 9 Page 9 WARNING Rem...

Page 12: ...rection Exhaust Exhaust Exhaust 4 or 6 Exhaust Voltage V Voltage V Frequency Hz Frequency Hz Noise sones Noise sones Speed rpm Speed rpm Power W Power W Fan Fan Lighting unit Lighting unit Weight lb W...

Reviews: