10. Insert the grille mounting spring on the wiring 

      side into the slot. (Fig.8)

13. Insert the other mounting spring into the slot as

      shown and mount grille to fan body. (Fig.9)

12. Adjust Pick-A-Flow switch.(Refer to indication on

      FEATURE)

9. Finish ceiling work. Ceiling hole should be aligned

    with the inside edge of the flange. (Fig.7) 

Mount grille carefully so that lead wire is not

pinched.

CAUTION

10 1/2 

(270)

10 1/2 

(270)

Fig.7

Unit: inches (mm)

After finishing the ceiling job, fill gap between flange
and ceiling with caulk or other sealant to prevent air
leakage

Ceiling

8. Insert fan body and slide into adapter assy 

    with some strength, until the flange overlaps

    the Flex-Z Fast     bracket. Secure the fan 

    body to Flex-Z Fast     bracket by using 2 

    self-drilling screws, plug connector to 

receptacle and secure the fan body to adaptor 

    by using machine screw (M4X8). (Fig.6)

TM

TM

Secure machine screw (M4X8) to the 

suitable hole and not touch the Flex-Z 

Fast     bracket. Please fix the screw 

carefully to avoid screw slip teeth.

TM

Machine

screw

(M4X8)

2 Self-drilling 

screws

Joist

Plug connector

Receptacle

Fig.6

CAUTION

CAUTION

INSTALLATION (NEW CONSTRUCTION) CONTINUED

Ceiling

Fig.8

Clasp

9

11. Insert the motion sensor on the grille and dress

 the wire as shown. (Fig. 8) 

Motion Sensor

(FV-0511VQC1
only).

Fig.9

Grille

Ceiling

Gloves

Mounting spring

Summary of Contents for FV-0511VQ1

Page 1: ... THESE INSTRUCTIONS Representative models FV 0511VQ1 FV 1115VQ1 Ventilating Fan FV 0511VQC1 Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product Please carefully read the GENERAL SAFETY INFORMATION Failure to comply with instructions could result in personal injury or property damage Please ex...

Page 2: ...njury to persons observe the following Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warn...

Page 3: ...ating fan where interior room temperature may exceed 104 F 40 C This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always discon...

Page 4: ... screw Warranty sheet Part name Part name Appearance Quantity Grille 4 TM Flex Z Fast bracket with 4 tapping screws ST4 2X20 1 Appearance Quantity FV 0511VQC1 only This Panasonic ventilating fan model is equipped with a motion sensor and a humidity sensor that turn on automatically when motion is detected when humidity increases rapidly or when humidity rises above a 30 80 relative humidity set po...

Page 5: ...3 5 4 1 2 114 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 3 3 8 86 6 5 8 169 10 1 4 261 13 330 3 7 8 100 3 7 8 100 1 1 2 37 8 1 7 7 3 6 4 8 9 2 1 5 5 3 6 2 11 4 10 9 Part name Grille Blade Junction box Adaptor PCB box Part name No No Pick A Flow switch Fan body Damper Motion sensor location 5 6 7 8 9 1 11 4 2 3 10 Selector TM Flex Z Fast bracket Part...

Page 6: ...rcuit Fan body DC Motor Junction box AC120V 60Hz Power supply White Black Live Fan Neutral Green Ground wire Main control circuit Main control circuit Factory setting 20 minutes Position For factory use Factory setting is around 50 Timer preset selector positions Timer min Humidity preset selector Selector indications on blower unit Timer preset selector Humidity selector range from around 30 to 8...

Page 7: ... static pressure which can hinder the performance of most ventilation fans This fan utilizes Smart Flow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within the ducts This feature allows the fan to perform as rated and avoid potential installation issues The WhisperCeiling ventilating fans...

Page 8: ...ING DIAGRAM Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 5 2 Tapping screws ST4 2X20 Bend down 4 tabs Joist Fig 3 Joist 2 Tapping screws ST4 2X20 2 Self drilling screws Knock out hole Junction box cover Conduit Circular duct Mastic or approved foil tape Fig 4 INSTALLATION ...

Page 9: ...age Ceiling 8 Insert fan body and slide into adapter assy with some strength until the flange overlaps the Flex Z Fast bracket Secure the fan body to Flex Z Fast bracket by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using machine screw M4X8 Fig 6 TM TM Secure machine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fi...

Page 10: ... Secure the Flex Z Fast bracket to joists by drilling 4 tapping screws ST4 2x20 which have been fixed on it Existing ductwork and wiring left in place Fig 10 TM TM 3 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 11 TM 4 Secure the fan body to Flex Z Fast bracket by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using...

Page 11: ...in the attic Our fans does not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors do not create enough ambient heat to be subjected to these limitations The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest str...

Page 12: ...10420B SPECIFICATIONS PRODUCT SERVICE Panasonic Corporation of North America Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 www panasonic ca Two Riverfront Plaza Newark NJ 07102 www panasonic com Model No Air direction Exhaust 4 or 6 Exhaust Voltage V Frequency Hz Noise sones Speed rpm Power W Weight Ib kg Duct diameter inches Air volume at 0 1 WG CFM FV 0511VQ1 FV 1115VQ1 110 ...

Reviews: