background image

English

SUPPLIED ACCESSORIES

UNPACKING

Unpack and carefully remove the unit from carton.

Refer to the Supplied Accessories list to verify that all parts are present.

1

1

1

Installation

instructions

Self-drilling

screw

Warranty

sheet

Part name

Part name

Appearance

Quantity

Grille

4

TM

Flex-Z Fast

bracket

(with 4 

tapping screws

   -ST4.2X20)

1

Appearance

Quantity

FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. This equipment generates, uses and can radiate radio 

frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference will not occur in 

a particular installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning this product on and off, the user is encouraged to try to correct the 

interference by one of the following measures:

Warning: This equipment must be installed by qualified person in accordance with the provided installation

instructions; and all applicable codes and standards. Also, any changes or modifications not expressly

approved by the party responsible for compliance could void the user’s authority to operate this equipment.
 DoC Responsible Party:            Panasonic Corporation of North America

                                                   Two Riverfront Plaza, Newark, NJ 07102

 Customer Call Center:            1-866-292-7299
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation.

Risk of Fire: Type IC-Inherently Protected.

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect equipment into outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

DESCRIPTION

These products are listed by UL under UL file No. E78414.

These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is

designed to have long operating life, high dynamic response, higher speed ranges with saving energy.

The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter

flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The

lighting unit is an energy-saving LED lighting device that uses one 10W LED lamp and produces almost the 

same illumination as a standard 40W incandescent lamp. Night light feature consumes around 0.1 to 0.4 W.

(FV-0511VQCL1 only)

This Panasonic ventilating fan model is equipped with a motion sensor and a humidity sensor that turn 

on automatically when motion is detected, when humidity increases rapidly, or when humidity rises above 

a 30% ~ 80% relative humidity set-point. It is user-adjustable to operate 0.5 ~ 60 minutes after the sensors 

are no longer detected.

4

Summary of Contents for FV-0511VQL1

Page 1: ...t after installation and this booklet should be presented to users Please retain this booklet for future reference Representative models FV 0511VQL1 FV 1115VQL1 FV 0511VQCL1 Ventilating Fan FV 1115VQL...

Page 2: ...d by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power f...

Page 3: ...ntrol device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occ...

Page 4: ...orth America Two Riverfront Plaza Newark NJ 07102 Customer Call Center 1 866 292 7299 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This dev...

Page 5: ...0 5 7 8 151 13 330 7 1 2 190 1 1 4 30 4 1 2 114 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 10 1 4 261 13 330 3 7 8 100 1 1 2 37 Part name Grille Blade...

Page 6: ...ht Live Fan Live N Light Neutral Neutral lue White Black Green Main control circuit Fan body LED DC Motor Junction box AC120V 60Hz Power supply AC120V 60Hz Power supply White Black Live Light Live Fan...

Page 7: ...Pick A Flow speed options The Pick A Flow switch on the face of all WhisperCeiling ventilating fans allow the option to choose 50 80 110 CFM for the FV 0511VQL1 or 110 130 150 CFM for the FV 1115VQL1...

Page 8: ...as the spacing between joists and install to joists by drilling the other 2 tapping screws which have been fixed on it Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction...

Page 9: ...her mounting spring into the slot as shown and mount grille to fan body Fig 9 12 Adjust Pick A Flow switch Refer to indication on FEATURE 9 Finish ceiling work Ceiling hole should be aligned with the...

Page 10: ...chine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth TM Fig 12 CAUTION WARNING WARNING Disconnect power source before wo...

Page 11: ...oblem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors do not create enough ambient heat to be subjected to these limitations The ducting from...

Page 12: ...a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA or 1 800 669 5165 Canada Printed in Mexico P0717 0 11QCL1420B PRODUCT SERVICE Panas...

Reviews: