background image

8

http://panasonic-electric-works.net/sunx

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

Europe Headquarter: Panasonic Electric Works Europe AG

Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany

Phone: +49-8024-648-0

US Headquarter: Panasonic Electric Works Corporation of America

629 Central Avenue, New Providence, New Jersey 07974, USA

Phone: +1-908-464-3550

16

sPEcIFIcatIons

Item

standard

long sensing range

FX-101-Z (NPN output)

FX-102-Z (NPN output)

FX-101P-Z (PNP output)

FX-102-PZ (PNP output)

Supply voltage

12 to 24V DC±10% Ripple P-P 10% or less (within the rated range)

Power consumption

Normal operation: 720mW or less 
(Current consumption 30mA or less at 24V supply voltage)
ECO mode: 600mW or less 
(Current consumption 25mA or less at 24V supply voltage)

output

NPN output type

NPN open-collector transistor

 

Maximum sink current: 100mA

 

Applied voltage: 30V DC or less (between output and 0V)

 

Residual voltage: 1.5V or less (at 100mA sink current)

PNP output type

PNP open-collector transistor

 

Maximum source current: 100mA

 

Applied voltage: 30V DC or less (between output and +V)

 

Residual voltage: 1.5V or less (at 100mA source current)

output operation

Light-ON or Dark-ON, selectable

short-circuit protection

Incorporated

External input

NPN output type

NPN non-contact input

 

Signal condition: 
High: +8V to +V DC or Open  
Low: 0 to +2V DC (Source current 0.5mA or less)

 

Input impedance: Approx. 10k

W

PNP output type

PNP non-contact input

 

Signal condition  
High: +4V to +V DC(Sink current 0.5 to 3mA or less)  
Low: 0 to +0.6V DC or Open 

 

Input impedance: Approx. 10k

W

response time

 

Emission frequency 0:250

m

s or less

 

Emission frequency 1: 450

m

s or less

 

Emission frequency 2: 500

m

s or less

 

Emission frequency 3: 600

m

s or less

 

Emission frequency 1: 2.5ms or less

 

Emission frequency 2: 2.8ms or less

 

Emission frequency 3: 3.2ms or less

 

Emission frequency 4: 5.0ms or less

Ambient temperature

-10 to +55˚C (No dew condensation or icing allowed, see note)

Storage: -20 to +70˚C

Ambient humidity

35 to 85% RH, Storage: 35 to 85% RH

Emitting element

Red LED (peak wavelength = 632nm)

Material

Enclosure: Polycarbonate, Fiber lock lever: PBT

Weight

Approx. 15g (Main body only)

When using the products in parallel, the ambient temperature is as follows: 4 to 7 units: -10 to +50˚C, 8 to 16 units: -10 to +45˚C

Summary of Contents for FX-100-Z Series

Page 1: ...t and steam Take care that the product does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkalines This product cannot be used in an environment containing inflam mable or explosive gases Never disassemble or modify the product EEPROM is adopted to this product Teaching is limited to 100 000 times because of the EEPROM s lifetime 2 Part DEscrIPtIon 1 6 5 ...

Page 2: ...run MoDE Digital display When you turn ON the power the product name is indicated in green and the emission frequency is indicated in red Then the device automatically switches into RUN mode in which the threshold value is displayed in green and the incident light intensity in red Power ON Emission frequency Product name RUN mode Incident light intensity Threshold value Automatic What appears on t...

Page 3: ...ttle margin between the theshold value and incident light intensity is al lowed for the environment when teaching 2 point teaching 2 point teaching is the most common teaching method and means the threshold value is taught using two points that correspond to the object present and object absent conditions Light ON or Dark ON is determined automatically for the output operation setting Output indic...

Page 4: ...n the threshold value follow up cycle is set the threshold value is adjusted according to the shift based on the incident light intensity detected However the threshold value is not stored GETA function note 4 5 Variations can be reduced by setting the present incident light intensity for each amplifier to a certain value For example if this value is set to 2 000 and the incident light intensity i...

Page 5: ... point Sampling in progress NPN output type High NPN output type Low 1 Depending on the threshold value output may turn ON OFF when emission is halted or released 2 When emission starts output operation is undetermined during the response time If the output signal is received by a PLC for example set the amplifier s timer to 20ms response time or greater Example For the FX 101q Z with emission fre...

Page 6: ...to another amplifier repeat steps 3 to 7 If the power is not turned on at the same time the setting con tents may not be copied To cancel the setting copy function of the master amplifier 1 While the slave side amplifier is disconnected turn on the power of the master side amplifier 2 Press MODE for 2s 12 QuIcK sEttInG FunctIon Simply by selecting a quick setting number which are listed in the tab...

Page 7: ...1 0 4 3 2 1 4 3 2 1 45 40 35 30 25 20 15 10 5 50 E_oF E_of LtcP Ltc Auto Eco LtcP Ltc Auto Eco ON OFF Code 1st digit 4th digit 3rd digit 2nd digit Output operation Timer see note Emission amount setting Emission frequency ECO External input Shift see note For differences between the conventional and modified units see unIt VErsIons on page 7 14 Error InDIcatIon If the follow error codes are displa...

Page 8: ...ansistor Maximum source current 100mA Applied voltage 30V DC or less between output and V Residual voltage 1 5V or less at 100mA source current output operation Light ON or Dark ON selectable short circuit protection Incorporated External input NPN output type NPN non contact input Signal condition High 8V to V DC or Open Low 0 to 2V DC Source current 0 5mA or less Input impedance Approx 10kW PNP ...