The indicator flashes
in red.
R
The battery charging terminals are dirty. Clean the
terminals.
R
Charging did not end properly or too much voltage
was detected. Remove and reinsert the battery or
the AC adaptor plug.
R
Battery authentication failed because an
unsupported battery was installed. Use only
specified batteries.
R
The battery may be worn out. Replace the battery
with a new one.
The indicator flashes
in orange.
R
The ambient temperature is too low or too high.
Charge the battery in environments with an ambient
temperature of 10 °C to 35 °C (50 °F to 95 °F).
Specifications
Power supply input
16 V DC, 3 A
Battery charging
4.35 V DC, 3 A
Battery charging time
FZ-VZSUN110U:
Approx. 2 hours (25 °C [77 °F] environment)
FZ-VZSUN120U:
Approx. 3 hours (25 °C [77 °F] environment)
External bus connector
9 pins
LAN port
(10Base-T/100Base-TX)
´
1
USB port
USB 2.0
´
2
Dimensions (W
´
D
´
H)
Approx. 143 mm
´
194 mm
´
99 mm
(5.7 in.
´
7.7 in.
´
3.9 in.)
(excluding protrusions)
Weight
Approx. 0.52 kg (1.2 lb)
Operating environment
0 °C to 40 °C (32 °F to 104 °F)
30 % to 80 % relative humidity
AC adaptor
Input: 100 V to 240 V AC, 50 Hz/60 Hz
Output: 16 V DC, 3.75 A
*1 Varies depending on usage conditions.
*2 Operation of all USB-compatible peripherals is not guaranteed.
*3 <Only for North America> The AC adaptor is designed for use with power
sources that supply up to 240 V AC. The AC cord supplied with the AC
adaptor is designed for use with power sources that supply up to 125 V AC.