background image

Part Names and Functions

10

2

Power port

MAC Address label

Serial number label

Power cord hook block

10BASE-T/100BASE-TX/1000BASE-T port

Back panel

 Power port

Connect the supplied power cord to this port and connect the other end into an 
electric outlet.

 Power cord hook block

If the supplied power cord is hanged to this block, the cord becomes hard to pull 
out from the power port.

  

Ground terminal

Connect the ground cable (AWG18: green/yellow) to the ground terminal screw.

 10BASE-T/100BASE-TX/1000BASE-T port (ports 1–12)

Connect 10BASE-T/100BASE-TX/1000BASE-T terminals, hubs, repeaters, bridges, 
and Ethernet Switches.
Install the device so that the length of the twisted pair cables (CAT5e or above) will 
be 100 m or less.

 PoE power supply ports (ports 1–10)

The port can supply PoE power conforming with IEEE802.3at. Connect a Powered
Device conforming with IEEE802.3at. Devices such as 10/100/1000BASE-T terminal,
hub, repeater, bridge, and Ethernet Switch can be connected to this port. Install the
device so that the length of twisted pair cable (Cat5e or above) becomes 100 m or
less.

Ground terminal

Front panel

Summary of Contents for GA-AS10TPoE+ Series

Page 1: ...stomers are not covered by the warranty I0916 50722 Printed in Japan GA AS10TPoE PN25108 TH PN25108 MY PN25108 ID PN25108 SG PN25108 NZ Model No The instruction manuals Menu Version CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato ku T...

Page 2: ...ct 1 Product Outline 1 1 Features 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting to rack 3 3 Configuration of IP address Basic Troubleshooting 3 6 7 7 8 9 9 10 12 12 13 14 16 ...

Page 3: ...to fire electric shock and or equipment failure Do not connect equipments other than 10BASE T 100BASE TX 1000BASE T to twisted pair port When connecting to a 10BASE T device use a Cat5 or above cable Deviation could lead to fire electric shock and or equipment failure Do not place this Ethernet Switch in harsh environment such as near water high humid and or high dust Deviation could lead to fire ...

Page 4: ...ion could lead to electric fire shock and or malfunction If the STATUS Status LED blinks in orange system fault unplug the power cord since this is a sign of maIfunction Deviation such as keep connecting for a long time could lead to fire Handle the Ethernet Switch carefully to prevent fingers and hands from being damaged by twisted pair port or power cord hook block Up to two Ethernet Switches ca...

Page 5: ...ht decrease due to the age related degradation etc of components It is recommended that this Ethernet Switch be replaced about five years after it has been installed Be careful in regards to environmental restrictions whereby the Ethernet Switch can be used Please isolate the business power lines and communication lines Isolate distribution lines and other distribution lines and low current power ...

Page 6: ...ble static charge such as carpet Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Please use this Ethernet Switch in place where ambient temperature is from 0 to 50 C Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covere...

Page 7: ...o be made The factory default is for ports 1 to 10 to have MDI X be fixed Equipped with IEEE802 3az LPI compatible Energy Efficient Ethernet functions hereinafter EEE and if data is transmitted when linked up the energy efficient state will be moved to whereas each port can suppress power consumption Automatically detects the connection states via the equipped energy efficiency mode and suppresses...

Page 8: ...pports 4 priority queues Management method WEB control screen ZEQUO assist Plus Power supply function Ports 1 to 10 support the IEEE802 3at compatible power supply function Maximum power supply 30 W per port 70 W in total Power supply method Alternative A Using idle line 1 2 3 6 Others Port Monitoring Storm control Power supply AC 100 240V 50 60 Hz 1 7 A Power consumption Normally Max 89 6 W 12 1 ...

Page 9: ...equently the POWER power LED lights up green and the STATUS status LED lights up orange and the hardware runs a self diagnostic When it is finished both the the POWER power LED and STATUS status LED light up green and it operates as an Ethernet Switch As this Ethernet Switch succeeds in communicating with a terminal connected to each port LED of the port lights up When the terminal is not operatin...

Page 10: ... ground terminal screw 10BASE T 100BASE TX 1000BASE T port ports 1 12 Connect 10BASE T 100BASE TX 1000BASE T terminals hubs repeaters bridges and Ethernet Switches Install the device so that the length of the twisted pair cables CAT5e or above will be 100 m or less PoE power supply ports ports 1 10 The port can supply PoE power conforming with IEEE802 3at Connect a Powered Device conforming with I...

Page 11: ... PoE limit LED Off Supplies power in a range of 0 63 W Green Light Supplies power in a range of 63 W 70 W Green Blink When the requested power supply capacity exceeds 70 W overload of the device overall Port LED Left LINK ACT ports 1 12 LED Green Light Link is established Green Blink Data is being sent received Off No terminal is connected Port LED Right PoE ports 1 10 LED Green Light Power is sup...

Page 12: ...unding cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normaI operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable ...

Page 13: ... and eight screws for fixing the rack mount brackets to the Ethernet Switch supplied with the mount brackets to fix the mount brackets to the four holes on one side of the Ethernet Switches Then use the two connection brackets and eight screws for fixing the connection brackets supplied with the mount brackets to securely fix the connection brackets to the connection screw holes on the front and b...

Page 14: ...dcast domain In a few seconds the screen displays the list of detected Ethernet Switches Screen 2 4 From the list of the detected Ethernet Switches select a device that you want to configure In the Setting item field in the lower part of the screen configure Network setting Switch name and other items 5 Fill in the setting items and press the Setting execution button to display the confirmation sc...

Page 15: ...15 For detailed settings and administration methods please see the PDF version of the Operating Instructions on Panasonic s website Screen 2 Screen 3 Screen 4 ...

Page 16: ...failing Set this device s port setting or the terminal s setting to half duplex Communications are slow Are the communication speed and mode settings correct If the proper communication mode signal cannot be obtained apply half duplex mode Please reconfirm Auto negotiation setting Is the utilization ratio of the network to which this Ethernet Switch is connected not too high Try separating this Et...

Page 17: ...oaded Is the Powered Device connected to the port compliant with the IEEE802 3at standard or IEEE802 3af standard Port LIM LED is blinking green Ensure that the total power supply demand from PoE powered devices does not exceed 70 W When the power supply is suddenly shut off Confirm that a single port is not overloaded Port LED right is not blinking Green or that the power supply capacity for the ...