GP-X
GP-A
High Speed High Accuracy Eddy Current Type Digital Displacement Sensor
GP-X
SERIES
High-speed sampling and high resolution. The new choice for
even more variegated data collection and processing.
Conforming to
EMC Directive
They perform with a ±0.3 % F.S. linearity for stainless steel and iron
Because they perform with a ±0.3 % F.S.
linearity, they can be used for sensing stainless steel
and iron enabling precise measurements not affected
by the work’s material. Specifications corresponding
to each material (stainless steel, iron, aluminum) has
already been inputted in the controller enabling the
easy selection of the setting that is most suitable for
the particular material used.
Distance
Distance
Before correction
After correction
Output valu
e
Aluminum
Iron
Stainless steel
Output valu
e
Optimal correction of the output feature
With a 25 μs ultra high sampling speed, the
GP-X
series
won’t miss even high speed work displacements.
With high resolution, 0.02 % F.S. (Note), they can perform
high-accuracy measurements of micro-displacements.
In particular, the sensor head
GP-X3SE
for 0.8 mm
0.049 in
sensing can differentiate ultra micro displacement
of 0.32 μm
0.013 mil
(Average number of samples: 64).
These devices boast a 0.07 % F.S./°C
temperature characteristics
By combining the sensor head with the controller, we’ve
realized 0.07 % F.S./°C. They are highly resistant to
ambient temperature changes enabling stable micro-
displacement measurements.
We’ve realized a 25 μs (40,000 times/sec.)
ultra high sampling speed
They possess a 0.02 % F.S. resolution for
highly accurate measurement
Note:
GP-XC3SE
and
GP-XC5SE
Resolution: 0.04 % F.S.
panasonic-electric-works.net/sunx
■
Glossary of terms.......................... P.1397
■
General precautions ..................... P.1405
■
General terms and conditions ........... F-17
■
Sensor selection guide .................. P.967~