Notes – Warning system
292
Warning system
When an error is detected right after the unit is turned on or during the operation, the occurrence of the error is notified in the
camera image screen of the LCD monitor or by the tally lamps. Deal with the error by following the indications.
Cases indicated by error messages
*1 Displayed when using
.
*2 Displayed when using
.
System error
Warning
Screen display
Description
Behavior and cause
Camera image screen
[SYSTEM ERROR]
An error in the standard signal or
communication error has occurred.
All of the tally lamps and the card access lamps (orange)
flash 4 times each second, and an alarm sounds.
•
Set the power switch to <OFF> and turn off the power.
Screen display
Description
Behavior and cause
Camera image screen
[LOW BATTERY]
Remaining battery level is insufficient. All of the tally lamps and the card access lamps (orange)
flash 4 times each second, and an alarm sounds.
The power status display becomes
, and it will flash once
every second in red.
•
The power is turned off in approximately 5 seconds.
•
Replace with a fully charged battery, or connect the AC
adaptor.
[HIGH TEMPERATURE]
Displayed when the internal
temperature of the main unit has risen
above assumed.
All of the tally lamps and the card access lamps (orange)
flash 4 times each second, and an alarm sounds.
•
The power is turned off in approximately 5 seconds.
•
Turn on the power again and check recording and playback
operations. If the problem persists, consult the dealer.
[FAN STOPPED]
The fan has stopped.
•
Recording is stopped.
•
The power turns off approximately 1 minute later.
•
Stop the use immediately when the fan has stopped, and
consult the dealer.
•
If the fan has stopped, temperature of the unit will rise.
Therefore, do not use the unit for a long period of time.
[REC WARNING]
An error of the recording data has
occurred during recording, and the
recording has stopped.
All of the tally lamps and the card access lamps (orange)
flash 4 times each second, and an alarm sounds.
•
Recording is stopped.
It has tried to record exceeding the
maximum number of clips during
recording.
All of the tally lamps and the card access lamps (orange)
flash 4 times each second, and an alarm sounds.
•
Recording is stopped.
•
[REC WARNING] [<OVER MAX NUM. OF CLIPS>] is
displayed in the warning display field of the STATUS
screen for the mode check.
•
Replace the memory card or delete unnecessary clips.
[Below functions are temporarily
disabled due to a rise of the camera’s
internal temperature. Please wait for
the camera to cool down.
- VIDEO RECORDING
- PRE REC
- USB TETHERING]
*1
Displayed when the internal
temperature of the main unit has risen
above assumed.
All of the tally lamps and the card access lamps (orange)
flash 4 times each second, and an alarm sounds.
•
Recording stops if it was in progress.
•
Streaming stops if streaming via USB tethering was in
progress.
•
[RECORDING] menu
¨
[PRE REC] is fixed to [OFF]
•
Wait until the temperature of the unit decreases.
[Below functions are temporarily
disabled due to a rise of the camera’s
internal temperature. Please wait for
the camera to cool down.
- VIDEO RECORDING
- PRE REC
- USB-LAN]
*2
Displayed when the internal
temperature of the main unit has risen
above assumed.
All of the tally lamps and the card access lamps (orange)
flash 4 times each second, and an alarm sounds.
•
Recording stops if it was in progress.
•
Streaming stops if streaming via a USB ethernet adaptor
was in progress.
•
[RECORDING] menu
¨
[PRE REC] is fixed to [OFF]
•
Wait until the temperature of the unit decreases.