77
Function menus
<50P IN/OUT ASSIGN>
50-pin assignment factory settings
Pin
no.
I/O
Setting item
1
I
REC
2
I
PLAY
3
I
FF
4
I
REW
5
I
STOP
6
I
___
7
I
___
8
I
422 REMOTE ON
9
I
422 REMOTE OFF
10
I
LOCAL ENABLE
11
I
EJECT
12
I
IN SET
13
I
REC INH ALL
14
I
REC INH PRE
15
I
LOCAL DISABLE
16
I
TC EXT
17
I
TC INT&TCG MODE AUTO
18
I
___
19
I
___
20
I
STNDBY ON/OFF
21
O
ERR0 STATUS
22
I
DET STOP ON
23
I
CUE
24
O
ERR1 STATUS
25
I
DET STOP OFF
26
Power
27
O
REC STATUS
28
O
PLAY STATUS
29
O
FF STATUS
30
O
REW STATUS
31
O
STOP STATUS
32
O
422 REMOTE STATUS
33
O
EJECT STATUS
34
O
ERR2 STATUS
35
O
TC SRC1 STATUS
36
O
TC SRC2 STATUS
37
O
___
38
O
___
39
O
REC INH1 STATUS
40
O
REC INH2 STATUS
Pin
no.
I/O
Setting item
41
O
CUE STATUS
42
O
REMOTE STATUS
43
O
DET STOP STATUS
44
O
PRE CTL DETECTED STATUS
45
O
LOCAL ENABLE STATUS
46
O
STANDBY ON STATUS
47
GND
48
O
___
49
GND
50
GND
“__” denotes that nothing is subject to control or to a status.
50P IN/OUT
ASSIGN
<Notes>
• For a command, input TTL level signals; for an
active low edge, input an electrical signal of 100 ms
or more.
• For a status, a maximum open collector and sink
current of 6 mA is output.
Summary of Contents for HD1700pe
Page 133: ...133 ...