2
3
Wiring
Remote zero-adjustment
Brown connect with 12
–
24V DC ±10%
Blue connect with 0V DC
Press and hold the keys UP and DOWN simultaneously for 3 seconds
+
V
0V
External
input
Control
output
Analog voltage output (0-5 V)/
current output (4-20mA)
Analog ground (shielded)
Assign any one.
Teaching
Zero set
Trigger
Emission stop
Part description
UP key
TEACH key
Laser emission indicator (green)
Output operation indicator (orange)
Teaching indicator (yellow)
Zero set indicator (yellow)
DOWN key
PRO mode indicator (yellow)
Digital display (red)