3.1 Installation Method
1.
When mounting this product, use M3 screws (prepare separately). Tighten the screws to a
torque of 0.5 N∙m or less.
● When using multiple sensors, mount them so that emitted laser beams do not directly
enter the beam receiving parts of other sensors in order to avoid mutual interference.
Also, mount them so that spot beams irradiated on a workpiece do not overlap with
those of other sensors.
● To prevent the product from falling due to loose screws, take prevention measures
such as using screws with washers depending on the operating environment.
● Do not mount the sensors closely side by side to prevent heat generation. Otherwise,
the product temperature may exceed the specified temperature due to heat
generation.
Use the tightening torque of 0.5 N∙m or less even when using the simple mounting bracket
MS-HG-01
(optional).
3.1 Installation Method
3-2
WUME-HGF1UM-2