5.15 Timer Setting
■
Overview
This setting is used to set the control output timing from ON to OFF or from OFF to ON.
Set value
Operation
OFF (No timer)
No change is made in the control output timing.
Off delay
When the control output is turned OFF from ON, delays the OFF output for the
timer’s time.
On delay
When the control output is turned ON from OFF, delays the ON output for the
timer’s time.
One-shot
When the control output is turned ON from OFF, holds the ON output for the timer’s
time and then outputs OFF output.
● When the timer is set or the timer’s time is changed during output delay operation, the changed
set value is reflected when the output is changed next time.
■
Setting method
● If you do not make key operation for 3 seconds after changing the threshold value, the changed
value is set as a new threshold value and the screen returns to the measurement display.
Setting item
Set value
Default value
Timer setting
OFF (non)
OFF delay (oFd)
ON delay (ond)
One-shot (oSd)
non
5.15 Timer Setting
WUME-HGF1UM-2
5-37