7.2.13 Reverse of Measured Value (
)
This function implements a mirror inversion of the judgment value at 0 mm as its base.
Set value
Judgment value range
Not reversed (FWD)
0.000 mm to 10.000 mm
Reversed (REV)
0.000 mm to -10.000 mm
The measured value reversal function can be set only when the detection mode is set to auto
edge detection mode, edge detection mode, or user assigned edge mode.
■
Setting method
7.2 Advanced Settings (
)
WUME-HGT-6
7-51