7.6 Calibration Settings (
)
7.6.1 Calibration Selection (
)
This function allows you to reduce installation errors when replacing the sensor head, for
example.
Calibration settings
Set value
Function
Calibration selection
(CAL.SEL)
Default (DEFAUL)
Calibration is reset to the factory default state.
User settings (USER)
Calibration is executed according to the preset value
and span is corrected.
Measured value 1
(CL.SET1)
For span adjustment, the measured object is moved to
target point 1 and measured value 1 is obtained.
Adjusted value 1
(AJ.VAL1)
A target value for measured value 1 is numerically
input.
Measured value 2
(CL.SET2)
For span adjustment, the measured object is moved to
target point 2 and measured value 2 is obtained.
Adjusted value 2
(AJ.VAL2)
A target value for measured value 2 is numerically
input.
● In the following cases, calibration cannot be executed. "ERROR" is displayed in the digital
display section / MAIN (white).
• The magnitude relation between the target value and the measured value does not match
(the signs of the target value and measured value do not match).
• As a result of span adjustment, the adjusted magnification exceeds twice the factory default
span.
• The measured value is in an indeterminate state ("
" displayed).
• The measured value is outside the measurement range ("+OVER" or "-OVER" displayed).
• The measured value is in an alarm or error state.
■
Setting method
7.6 Calibration Settings (
)
WUME-HGT-6
7-67
Summary of Contents for HG-T Series
Page 2: ... MEMO 2 WUME HGT 6 ...
Page 28: ... MEMO 2 8 WUME HGT 6 ...
Page 96: ... MEMO 5 50 WUME HGT 6 ...
Page 99: ... Note 2 Displayed only during calculation 6 1 Flow of Measurement Data WUME HGT 6 6 3 ...
Page 128: ... MEMO 6 32 WUME HGT 6 ...
Page 158: ... No timer OFF 7 2 Advanced Settings 7 30 WUME HGT 6 ...
Page 177: ...Example Positioning a glass plate Setting method 7 2 Advanced Settings WUME HGT 6 7 49 ...
Page 218: ...8 2 3 Side View Attachment HG TSV10 Units mm 8 2 Dimension Drawings 8 14 WUME HGT 6 ...
Page 221: ...10 Troubleshooting 10 1 Troubleshooting 10 2 10 2 Error Messages 10 5 WUME HGT 6 10 1 ...
Page 229: ...Menu Structure General Function Display WUME HGT 6 App 3 ...
Page 231: ...Menu Structure Extended Function Display WUME HGT 6 App 5 ...
Page 232: ... MEMO App 6 WUME HGT 6 ...
Page 235: ... MEMO WUME HGT 6 ...
Page 236: ...Panasonic Industrial Devices SUNX Co Ltd 2020 PRINTED IN JAPAN WUME HGT 6 ...