8.1 Specifications
8.1.1 Controller
Measured at a supply voltage of +24 V DC and an ambient temperature of +20 °C, unless
otherwise indicated.
Type
Master unit
Slave unit
High-performance type
Wire-saving type
Model No.
NPN
output
HG-TC101
HG-TC111
HG-TC113
PNP
output
HG-TC101-P
HG-TC111-P
Number of connectable
units
Up to 15 slave units can be connected to a master unit. (Up to 14 slave units can be
connected if a communication unit is connected.)
Supply voltage
24 V DC ±10%, including 0.5 V ripple (P-P)
Current
100 mA or less (when sensor head is connected)
Analog
output
(Switching
type)
Analog
voltage
output
● Voltage output range: 1 to 5 V / F.S. (default value)
● Output when alarm occurs: 5.2 V
● Linearity: ±0.05% F.S.
● Output impedance: 100 Ω max.
―
Analog
current
output
● Current output range: 4 to 20 mA / F.S. (default
value)
● Output when alarm occurs: 0 mA
● Linearity: ±0.25% F.S.
● Load impedance: 250 Ω max.
―
Control output
(Output 1 / Output 2 /
Output 3)
NPN output type
NPN open-collector transistor
● Applied voltage: 30 V DC or less (between output
and 0 V)
● Residual voltage: 1.5 V or less (at 50 mA sink
current)
● Leakage current: 0.1mA or less
PNP output type
PNP open-collector transistor
● Maximum source current: 50 mA
● Applied voltage: 30 V DC or less (between output
and +V)
● Residual voltage: 1.5 V or less (at 50 mA source
current)
● Leakage current: 0.1 mA or less
―
Short-circuit protection
Incorporated (automatic reset type)
Judgment output
N.O. / N.C switching type
Alarm output
Open when alarm occurs
8.1 Specifications
8-2
WUME-HGT-6
Summary of Contents for HG-T Series
Page 2: ... MEMO 2 WUME HGT 6 ...
Page 28: ... MEMO 2 8 WUME HGT 6 ...
Page 96: ... MEMO 5 50 WUME HGT 6 ...
Page 99: ... Note 2 Displayed only during calculation 6 1 Flow of Measurement Data WUME HGT 6 6 3 ...
Page 128: ... MEMO 6 32 WUME HGT 6 ...
Page 158: ... No timer OFF 7 2 Advanced Settings 7 30 WUME HGT 6 ...
Page 177: ...Example Positioning a glass plate Setting method 7 2 Advanced Settings WUME HGT 6 7 49 ...
Page 218: ...8 2 3 Side View Attachment HG TSV10 Units mm 8 2 Dimension Drawings 8 14 WUME HGT 6 ...
Page 221: ...10 Troubleshooting 10 1 Troubleshooting 10 2 10 2 Error Messages 10 5 WUME HGT 6 10 1 ...
Page 229: ...Menu Structure General Function Display WUME HGT 6 App 3 ...
Page 231: ...Menu Structure Extended Function Display WUME HGT 6 App 5 ...
Page 232: ... MEMO App 6 WUME HGT 6 ...
Page 235: ... MEMO WUME HGT 6 ...
Page 236: ...Panasonic Industrial Devices SUNX Co Ltd 2020 PRINTED IN JAPAN WUME HGT 6 ...